{"product_id":"990-05-xx-01-00-mod-167577-07-bently-nevada-990-series-vibration-transmitter","title":"990-05-XX-01-00 MOD 167577-07 Bently Nevada 990 Series Vibration Transmitter","description":"\u003cp\u003eConfigured for vibration signal conversion in Bently Nevada 990 monitoring systems, the \u003cstrong\u003eBently Nevada 990-05-XX-01-00 MOD 167577-07\u003c\/strong\u003e (\u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter) provides direct physical\/electrical execution for converting vibration measurements into transmitter output signals.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Overview\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-01-00 MOD 167577-07 configuration defines the vibration measurement range, system cable length option, mounting method, and approval selection. The unit supports 0-5 mils peak-to-peak vibration measurement and is configured for 35 mm DIN rail mounting.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-00 MOD 167577-07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e990 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 7.4 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRequires +12 to +35 VDC input at transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft) \/ 7.0 m (23.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Function\u003c\/td\u003e\n\u003ctd\u003eVibration measurement transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModel Selection Details\u003c\/h3\u003e\n\u003cp\u003eThe 990 series option structure identifies individual transmitter configuration parameters.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp) full-scale vibration range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXX\u003c\/td\u003e\n\u003ctd\u003eSystem length option identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo additional agency approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD 167577-07\u003c\/td\u003e\n\u003ctd\u003eSpecific transmitter assembly identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 990 Vibration Transmitter processes vibration measurement signals from compatible sensing systems and provides scaled vibration output for monitoring equipment. The transmitter configuration supports machinery vibration evaluation by converting sensor input data into a standardized monitoring signal.\u003c\/p\u003e\n\u003cp\u003eFor machinery diagnostic applications, signal scaling must correspond with the selected full-scale range. Proper configuration alignment prevents incorrect vibration amplitude interpretation during rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eGap Voltage and Vibration Monitoring Interface\u003c\/h3\u003e\n\u003cp\u003eBently Nevada monitoring systems use different sensor technologies depending on measurement requirements. Eddy-current probe systems typically require gap voltage validation and displacement scaling, while the 990 transmitter focuses on vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003eInstallation should maintain correct sensor wiring polarity, cable shielding, and grounding practices to reduce electrical noise and cross-talk effects in vibration measurement circuits.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 990-05-XX-01-00 MOD 167577-07 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e1 x 35 mm DIN rail mounting clip assembly\u003c\/li\u003e\n\u003cli\u003e1 x Standard transmitter hardware configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional sensors, cables, calibration records, software, and accessories are not included unless specifically listed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter on a compatible 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eVerify that the mounting clip is correctly engaged before wiring.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in an enclosure suitable for the operating environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSupply +12 to +35 VDC input power at the transmitter terminal.\u003c\/li\u003e\n\u003cli\u003eRoute vibration signal wiring separately from high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003eFollow shield termination practices specified by the monitoring system design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSignal Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the selected 0-5 mils pp measurement range matches the connected monitoring input.\u003c\/li\u003e\n\u003cli\u003eVerify system length settings before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck signal scaling after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat vibration range does the 990-05-XX-01-00 MOD 167577-07 support?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transmitter is configured for a full-scale vibration range of 0-5 mils peak-to-peak, equivalent to 0-125 um peak-to-peak.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat power supply does this transmitter require?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit requires a +12 to +35 VDC input supply connected at the transmitter terminal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat mounting method is used for this model?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transmitter uses 35 mm DIN rail clips for mechanical installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this model include an agency approval option?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 990-05-XX-01-00 MOD 167577-07 configuration specifies no additional agency approval option.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat system length options are available?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe configuration supports system length selections of 5.0 m (16.4 ft) and 7.0 m (23.0 ft).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan this transmitter directly replace an accelerometer?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The transmitter processes vibration measurement signals and requires compatible sensing equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow should signal wiring be installed?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal wiring should be separated from power conductors and installed using appropriate shielding and grounding methods.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs firmware configuration required for operation?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo firmware information is specified for this transmitter model. Configuration depends on hardware selection and system requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025223930029,"sku":"990-05-XX-01-00 167577-07","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990-10-xx-01-05_3dc68d4d-ef6f-4105-ad36-7369178543d6.jpg?v=1785737865","url":"https:\/\/www.maxwellplc.com\/ga\/products\/990-05-xx-01-00-mod-167577-07-bently-nevada-990-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}