{"product_id":"60m100-00-bently-nevada-60m-series-condition-monitoring-system","title":"60M100-00 Bently Nevada 60M Series Condition Monitoring System","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for high-speed signal acquisition in industrial diagnostic platforms, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"85\"\u003eBently Nevada 60M100-00\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"110\"\u003e60M100-00\u003c\/b\u003e Condition Monitoring System) provides direct physical execution of multi-channel dynamic data sampling and phase-referenced signal processing.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Suffix Analysis\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe 60M100-00 designation represents a specialized hardware configuration within the Bently Nevada 60M series. The base model number identifies the hardware's core processing capabilities, including support for 12 dynamic signal inputs and 2 Keyphasor synchronization signals, optimized for high-bandwidth data acquisition requirements.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Technical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003e60M100-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e1.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e2 x 19 x 12.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003eConsult 60M Series technical manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e1.7 A (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e18 Vdc to 36 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eInrush Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e2.7 A (less than 5 ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eDynamic Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e110 dB @ fs = 102.4 ksps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eBandwidth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e0 to 40 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eA\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eSigma-Delta 24 bits nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe system utilizes advanced signal processing to maintain rotor dynamics accuracy. Dynamic range and signal-to-noise performance are validated at 110 dB with a sampling frequency of 102.4 ksps. Precise eddy-current probe scaling is necessary to interpret inputs correctly, as the system relies on gap voltage validation at -10 VDC targets for optimal linear operation. Furthermore, integrated cross-talk suppression ensures that high-frequency vibration signals remain isolated from speed-referenced Keyphasor triggers, preserving the integrity of spectral analysis.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x 60M100-00 Condition Monitoring System unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Terminal connector kit for signal and power input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Technical documentation and regulatory compliance sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003ePower Requirements\u003c\/p\u003e\n\u003cul data-path-to-node=\"14,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,1,0,0\"\u003eEnsure the DC power supply remains within the 18 Vdc to 36 Vdc range to prevent operational instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,1,1,0\"\u003eVerify that the supply can handle the 2.7 A peak inrush current during the system power-up cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eSignal Routing and Grounding\u003c\/p\u003e\n\u003cul data-path-to-node=\"14,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,1,0,0\"\u003eUtilize shielded twisted-pair cabling for all dynamic signal inputs to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,1,1,0\"\u003eEstablish a low-impedance ground connection to the chassis to ensure effective noise dissipation across the 40 kHz bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eDoes the 60M100-00 support hot-swapping?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eThe system is designed as a modular unit. While power can be cycled, refer to the manual regarding the specific procedure for module removal under power to avoid potential signal surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eWhat is the role of the 24-bit Sigma-Delta converter?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eThe 24-bit resolution ensures high-precision quantization of low-amplitude dynamic signals, which is essential for accurate frequency-domain analysis in machinery diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eCan I use this for TSI (Turbine Supervisory Instrumentation)?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eThe 60M series is designed for condition monitoring; confirm its specific safety and protection ratings against the requirements of your turbine protection scheme.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eHow is the Keyphasor signal utilized?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eThe two Keyphasor inputs act as once-per-revolution phase references, allowing the system to correlate dynamic vibration signals with rotor position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat is the impact of the 40 kHz bandwidth?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eThe 40 kHz bandwidth allows the system to capture high-frequency phenomena, such as gear mesh frequencies or blade pass transients, beyond standard low-frequency casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs the 1.7 A current draw continuous?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003e1.7 A represents the nominal operational current; the system must be powered by a source capable of handling this continuous draw plus the initial 2.7 A inrush.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eWhy is the sampling frequency set to 102.4 ksps?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eThis frequency is selected to satisfy Nyquist criteria for the 40 kHz bandwidth, ensuring minimal aliasing during the 24-bit A\/D conversion process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eHow do I calibrate the dynamic range?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eDynamic range is defined by the hardware architecture and A\/D performance; ensure input signals do not exceed the voltage limits to prevent clipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026830971053,"sku":"60M100-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/60M100-00_3_cdb0614a-b63d-41a0-9fd7-64e9ed4d8ea4.jpg?v=1782787553","url":"https:\/\/www.maxwellplc.com\/ga\/products\/60m100-00-bently-nevada-60m-series-condition-monitoring-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}