{"product_id":"5069-l306er-allen-bradley-programmable-automation-controller-compactlogix-5380","title":"5069-L306ER Allen-Bradley Programmable Automation Controller CompactLogix 5380","description":"\u003cp\u003eConfigured for high-speed motion task execution and digital signal processing in EtherNet\/IP networks, the \u003cstrong\u003eAllen-Bradley 5069-L306ER\u003c\/strong\u003e (\u003cstrong\u003e5069-L30\u003c\/strong\u003e Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eController Catalog Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5069\u003c\/strong\u003e: Bulletin series identifier for CompactLogix 5380 I\/O and controller system architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL306\u003c\/strong\u003e: Controller performance tier designating 0.6 MB application memory capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Integrated dual 10\/100\/1000 Mbps Ethernet communication ports for network routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Hardware execution supporting Device Level Ring (DLR) and embedded switch ring redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5069-L306ER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.84 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 135 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e45 W max (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Application Memory\u003c\/td\u003e\n\u003ctd\u003e0.6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Compact 5069 I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication\u003c\/td\u003e\n\u003ctd\u003eDual RJ45 Gigabit Ethernet Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported IP Nodes\u003c\/td\u003e\n\u003ctd\u003e32 EtherNet\/IP Nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage Module\u003c\/td\u003e\n\u003ctd\u003eRemovable Non-Battery Energy Storage (Embedded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEmbedded Backplane Communications \u0026amp; Firmware Flash Protocols\u003c\/h3\u003e\n\u003cp\u003eThe module routes high-density system tags across internal backplane buses at high communication speeds, maintaining real-time deterministic synchronization with field I\/O expansion blocks. Operating stability requires explicit firmware flash compatibility between controller execution engines and connected field devices over EtherNet\/IP networks. Dual Gigabit Ethernet ports allow high-throughput packet routing without degrading internal motion axis scan performance or backplane cycle execution timing.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 5069-L306ER Controller Unit\u003c\/li\u003e\n\u003cli\u003e1 x Right-End Backplane Cover Shield\u003c\/li\u003e\n\u003cli\u003e1 x 5069-RTB54 5-Pin Removable Power Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Mounting and Safety Directive Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Enclosure \u0026amp; Wiring Installation Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Attachment and Backplane Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMount the controller onto a standard 35 mm zinc-plated steel DIN rail. Slide adjacent 5069 I\/O expansion modules firmly along the side interlocking guide tracks until backplane connectors lock completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Power Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWire 24 VDC power conductors (16 to 14 AWG) to the removable 5069-RTB54 terminal block to supply System Power (MOD Power) and Field Power (SA Power) buses separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Grounding Execution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect a short, low-impedance ground braid from the DIN rail grounding terminal directly to the central panel earth bus bar to mitigate common-mode electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Cabling Rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse Category 6 STP (Shielded Twisted Pair) patch cables for dual RJ45 gigabit ports, routing network runs away from 480 VAC power lines and variable frequency drive output conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Hardware \u0026amp; Electrical Diagnostics FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limits exist for local 5069 I\/O expansion expansion banks?\u003c\/p\u003e\n\u003cp\u003eThe controller directly supports a maximum limit of 8 local Compact 5069 I\/O modules mounted directly on the right side of the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is system memory maintained during complete input power outages?\u003c\/p\u003e\n\u003cp\u003eAn internal non-battery energy storage module maintains system memory long enough to write active program registers into permanent non-volatile flash memory during power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan System Power (MOD) and Sensor\/Actuator Power (SA) share a single power supply?\u003c\/p\u003e\n\u003cp\u003eYes, a single 24 VDC power supply can feed both MOD and SA inputs, provided total current draw remains within terminal block rating limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do dual Ethernet ports operate when configured in Dual IP mode?\u003c\/p\u003e\n\u003cp\u003eIn Dual IP mode, each RJ45 port assigns a distinct IP address, physically separating enterprise network traffic from local machine control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the controller backplane support hot-swapping local 5069 I\/O modules?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting 5069 local I\/O modules while the backplane power bus is energized causes backplane communication faults and potential electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum number of EtherNet\/IP nodes can this model control?\u003c\/p\u003e\n\u003cp\u003eThe 5069-L306ER platform enforces a hard firmware connection limit capped at 32 active EtherNet\/IP network nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are status errors diagnosed on the physical front panel assembly?\u003c\/p\u003e\n\u003cp\u003eThe controller front housing features a multi-character scrolling LED display along with individual module status (MOD) and network status (NET) indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recommended screw torque for terminal block wiring connections?\u003c\/p\u003e\n\u003cp\u003eTerminal block wire clamping screws must be torqued precisely to 0.5 to 0.6 Nm to ensure tight gas-proof electrical contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47279678193837,"sku":"5069-L306ER","price":1288.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/5069-L306ER_2-1.jpg?v=1787207413","url":"https:\/\/www.maxwellplc.com\/ga\/products\/5069-l306er-allen-bradley-programmable-automation-controller-compactlogix-5380","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}