{"product_id":"3g3mx2-a4150-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4150-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eConfigured for high-torque 3-phase 400 V AC motor velocity regulation and dynamic drive execution in automated motion architectures, the \u003cstrong\u003eOmron 3G3MX2-A4150-ZV1\u003c\/strong\u003e (\u003cstrong\u003e3G3MX2\u003c\/strong\u003e) Multi-Function Compact Inverter provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; System Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base platform code for the MX2 Series compact inverter generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC voltage supply class rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150\u003c\/strong\u003e: Maximum applicable motor capacity of 15 kW under Heavy Duty (CT) loading profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Application-specific firmware integration option and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4150-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 18.0 cm x 17.55 cm (Shipping Weight: 8.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 kW rated motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Communication \u0026amp; Firmware Microcode Execution\u003c\/h3\u003e\n\u003cp\u003eThe internal drive control unit processes real-time bus commands via EtherNet\/IP deterministic networks and Modbus RTU serial links. Internal architecture leverages backplane bus communication velocity licences to maintain cycle synchronization without packet jitter. High I\/O density scaling accepts pulse sequence input frequencies up to 32 kHz, while firmware flash compatibility allows direct parameter flashing from host PLC software environments.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4150-ZV1 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x High-Voltage Terminal Protective Cover\u003c\/li\u003e\n\u003cli\u003e1 x System Installation \u0026amp; Wiring Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFrame Mounting Guidelines\u003c\/p\u003e\n\u003cp\u003eSecure the unit vertically onto a rigid metallic panel using M5 mounting hardware, providing at least 100 mm vertical clearance above and below the heat sink for unhindered forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Conductor \u0026amp; Signal Separation\u003c\/p\u003e\n\u003cp\u003eMaintain a physical separation distance of at least 100 mm between primary 400 V AC power conductors and 24 VDC I\/O or analog control wires to suppress electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Interface Rules\u003c\/p\u003e\n\u003cp\u003eRun a direct low-impedance ground lead from the protective earth terminal to the main panel earthing bar. Do not daisy-chain ground lines between multiple drive chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Hardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main power input terminals be wired while the supply line remains active?\u003c\/p\u003e\n\u003cp\u003eNo. Primary AC supply line isolation must be confirmed and internal DC bus capacitor voltage measured below 50 VDC prior to accessing terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal propagation delay occurs when the dual hardware safety inputs are triggered?\u003c\/p\u003e\n\u003cp\u003eThe integrated safety inputs execute direct gate driver disable within 10 milliseconds, stripping output motor torque in compliance with ISO 13849-1 Cat 3 PLd standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal serial interface resist industrial line surge transients?\u003c\/p\u003e\n\u003cp\u003eThe onboard RS485 communication port uses integrated galvanic isolation barriers to prevent differential ground potential offsets and common-mode noise corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the inverter unit capable of driving high-speed motor spindles exceeding 60 Hz limits?\u003c\/p\u003e\n\u003cp\u003eYes. Configurable microcode registers allow output frequency scaling up to 1000 Hz, provided motor mechanical speed ratings and winding insulation permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen is an external dynamic braking resistor required for deceleration cycles?\u003c\/p\u003e\n\u003cp\u003eAn external braking resistor must be wired to the DC bus terminals when high-inertia load regenerative energy exceeds the thermal dissipation limits of the internal chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current derating factor applies during continuous high-ambient temperature operation?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be reduced by 2.5% per deg C for ambient operating environments continuously exceeding 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes non-volatile memory require an auxiliary battery module for parameter persistence?\u003c\/p\u003e\n\u003cp\u003eNo. Parameter configurations, user-programmed sequence files, and historical fault data are permanently recorded in non-volatile internal EEPROM storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding method prevents analog reference voltage drift on 4-20 mA control loops?\u003c\/p\u003e\n\u003cp\u003eGround the cable braid shield to the drive earth point only at the inverter end. Leaving the remote end ungrounded prevents loop currents from corrupting control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306640621741,"sku":"3G3MX2-A4150-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4150-zv1_1.jpg?v=1787723092","url":"https:\/\/www.maxwellplc.com\/ga\/products\/3g3mx2-a4150-zv1-omron-mx2-series-multi-function-compact-inverter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}