{"product_id":"3axd50000042865-bdps-11c-abb-power-supply-board-s800-i-o","title":"3AXD50000042865 BDPS-11C ABB Power Supply Board S800 I\/O","description":"\u003cp\u003eConfigured for primary and backup DC power distribution in S800 I\/O architectures, the \u003cstrong\u003eABB 3AXD50000042865 BDPS-11C\u003c\/strong\u003e (\u003cstrong\u003eBDPS-11C\u003c\/strong\u003e Power Supply Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eOperational Parameters \u0026amp; Power Bus Topology\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Power Inputs\u003c\/strong\u003e: Accepts a primary DC input voltage range of 18 to 32 VDC along with a secondary auxiliary backup input rated at 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Regulation\u003c\/strong\u003e: Delivers a steady regulated continuous output of 24 VDC at up to 6 A rated drive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Quality \u0026amp; Hold Time\u003c\/strong\u003e: Exhibits typical operating efficiency exceeding 85%, output ripple\/noise under 100 mV peak-to-peak, and extended hold-up times greater than or equal to 48 hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3AXD50000042865 BDPS-11C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Efficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 85% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple and Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on backplane bus load (Not specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (-40 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd\u003eDNV\/GL, ABS, LR, BV (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.5 x 13.5 x 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Synchronization \u0026amp; System Execution\u003c\/h3\u003e\n\u003cp\u003eThe power board interfaces directly with internal chassis backplanes to power logic modules without degrading backplane bus communication velocity Licences. Low noise switching circuits prevent voltage spikes from interfering with precise data transactions across node connections. Dedicated internal memory flash compatibility maintains full operational continuity across System 800xA rack expansions under heavy load swings.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 3AXD50000042865 BDPS-11C Power Supply Board\u003c\/li\u003e\n\u003cli\u003e1 x Jumper Wire Harness Set\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Cable Routing Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Wire Configuration\u003c\/strong\u003e: Connect the supplied jumper wire harness across designated terminal blocks to configure primary and backup supply feed lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment\u003c\/strong\u003e: Insert the board assembly into its designated rack slot until the backplane connectors bind securely to the card cage header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Source Protection\u003c\/strong\u003e: Wire primary 18 to 32 VDC supply loops through properly rated inline fuses to prevent system damage under fault conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental \u0026amp; Shielding\u003c\/strong\u003e: Secure functional ground paths to cabinet earth studs to divert high-frequency transients and maintain thermal dissipation across the -40 to +70 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the primary and backup input voltage ranges for this power supply board?\u003c\/p\u003e\n\u003cp\u003eThe board accepts a primary input voltage between 18 and 32 VDC and a dedicated backup supply input rated at 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output current can the 3AXD50000042865 BDPS-11C continuously deliver?\u003c\/p\u003e\n\u003cp\u003eThe hardware unit supplies a regulated 24 VDC output with a maximum continuous load capacity of 6 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of ripple and noise is present on the 24 VDC output line?\u003c\/p\u003e\n\u003cp\u003eThe power conversion circuitry restricts output ripple and high-frequency noise to less than 100 mV peak-to-peak under normal load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the holdup time rating provided by the internal energy storage circuit?\u003c\/p\u003e\n\u003cp\u003eThe board circuit maintains output voltage stability with an extended holdup time spec of 48 hours or greater.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat marine classification society approvals are optioned for this hardware?\u003c\/p\u003e\n\u003cp\u003eThe board design meets optional marine type approval standards for DNV\/GL, ABS, LR, and BV classification requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the board package include required configuration jumper hardware?\u003c\/p\u003e\n\u003cp\u003eYes, each unit ships complete with the required jumper wire assembly for setting up input power configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is allowable for continuous site operation?\u003c\/p\u003e\n\u003cp\u003eThe power supply board operates continuously within extreme thermal environments ranging from -40 to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain power integrity during primary supply interruptions?\u003c\/p\u003e\n\u003cp\u003eIntegrated power transfer paths switch seamlessly to the 24 VDC backup input line without interrupting output power stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021038014637,"sku":"BDPS-11C 3AXD50000042865","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/BDPS-11C3AXD50000042865_2.jpg?v=1787400918","url":"https:\/\/www.maxwellplc.com\/ga\/products\/3axd50000042865-bdps-11c-abb-power-supply-board-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}