{"product_id":"3500-92-01-01-00-bently-nevada-communication-gateway-3500-series","title":"3500\/92-01-01-00 Bently Nevada Communication Gateway 3500 Series","description":"\u003cp\u003eConfigured for network protocol conversion and data aggregation in machinery monitoring networks, the \u003cstrong\u003eBently Nevada 3500\/92-01-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/92\u003c\/strong\u003e Communication Gateway, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation Feature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAssigned Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Module Series\u003c\/td\u003e\n\u003ctd\u003e3500\/92 Communication Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Option\u003c\/td\u003e\n\u003ctd\u003e01 (Modbus RS232\/RS422 I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Option\u003c\/td\u003e\n\u003ctd\u003e01 (Low Memory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00 (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Port Interface\u003c\/td\u003e\n\u003ctd\u003eRJ-45 Ethernet \u0026amp; Serial Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/92-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 25.6 x 24 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.0 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Link\u003c\/td\u003e\n\u003ctd\u003eEthernet 10 Mbps (IEEE 802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP frame and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; TSI Data Telemetry Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with downstream monitoring racks to stream real-time rotor dynamics metrics, gap voltage validation targets, and eddy-current probe scaling coefficients across external networks. Cross-talk suppression mechanisms isolate serial communication channels from internal power plane transients, ensuring high-integrity telemetry output for rotating machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 3500\/92-01-01-00 Communication Gateway Module\u003c\/li\u003e\n\u003cli\u003e1 x Associated Modbus RS232\/RS422 I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory Inspection Conformance Record\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Position\u003c\/strong\u003e: Install the gateway module into the designated slot positions within the front chassis while mating the associated I\/O module to the corresponding rear slot connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling\u003c\/strong\u003e: Connect shielded twisted-pair Ethernet cable to the front RJ-45 port conforming to IEEE 802.3 10 Mbps standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Termination\u003c\/strong\u003e: Wire serial communication lines securely to the rear I\/O module terminals, maintaining proper impedance matching for RS232 or RS422 protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding\u003c\/strong\u003e: Secure the rack frame earth connection to eliminate ground loops that can disrupt high-speed gateway telemetry transmissions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry \u0026amp; Technical Troubleshooting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this communication gateway support hot-swapping under power?\u003c\/p\u003e\n\u003cp\u003eA: Live insertion and removal is restricted; system power must be disconnected prior to sliding the module into or out of the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary network data transmission rate of the onboard Ethernet port?\u003c\/p\u003e\n\u003cp\u003eA: The communication link operates at a fixed rate of 10 Mbps compliant with IEEE 802.3 specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is power supplied to the 3500\/92 gateway module within the rack?\u003c\/p\u003e\n\u003cp\u003eA: Power is distributed directly through the backplane bus pins connected to the main rack power supply units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What serial communication protocols are supported by the type-01 I\/O option?\u003c\/p\u003e\n\u003cp\u003eA: The module supports Modbus communication protocols over physical RS232 and RS422 interface standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the low memory configuration be upgraded in the field?\u003c\/p\u003e\n\u003cp\u003eA: Memory expansion requires factory-authorized hardware replacement or specific module revision swapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What environmental humidity limits apply during operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit functions reliably within non-condensing relative humidity environments up to 95 percent RH.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the gateway handle network packet collisions on the bus?\u003c\/p\u003e\n\u003cp\u003eA: Internal buffer management handles standard TCP\/IP frame retransmissions according to IEEE 802.3 link rules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What diagnostic indicators are present on the front panel?\u003c\/p\u003e\n\u003cp\u003eA: LED indicators display power status, communication traffic flow, and internal hardware health conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025237790893,"sku":"3500\/92-01-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350092-33.jpg?v=1783503408","url":"https:\/\/www.maxwellplc.com\/ga\/products\/3500-92-01-01-00-bently-nevada-communication-gateway-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}