{"product_id":"3500-40-01-r0-bently-nevada-proximitor-monitor-3500-system","title":"3500\/40-01-R0 Bently Nevada Proximitor Monitor 3500 System","description":"\u003cp\u003eConfigured for multi-channel proximity transducer data acquisition in 3500 Machinery Condition Monitoring platforms, the \u003cstrong\u003eBently Nevada 3500\/40-01-R0\u003c\/strong\u003e (\u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor Monitor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/40\u003c\/strong\u003e: Base model designation for the Proximitor monitor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: I\/O module type option specifying internal termination without internal barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR0\u003c\/strong\u003e: Factory revision and mounting identifier associated with standard system builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/40-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain Module: 0.91 kg (2.0 lb); I\/O Module: 0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eMain: 241.3 mm x 24.4 mm x 241.8 mm; I\/O: 241.3 mm x 24.4 mm x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C (-22 deg F to +150 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling\u003c\/strong\u003e: Processes inputs from 1 to 4 proximity transducers, translating raw signals using selectable scaling factors such as 3.94 mV\/um (100 mV\/mil) or 7.87 mV\/um (200 mV\/mil) for radial vibration, thrust, and eccentricity measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation\u003c\/strong\u003e: Continuously monitors transducer gap voltages against -10 VDC targets to ensure linear displacement tracking and alert operators to transducer mechanical displacement or electrical drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression \u0026amp; Filtering\u003c\/strong\u003e: Utilizes advanced vector filtering, constant Q notch filters, and dedicated direct\/gap filter loops to isolate running speed components (1X, 2X, Not 1X, and Smax) while eliminating signal cross-talk across adjacent channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3500\/40M Main Monitor Module (Part Number 176449-01)\u003c\/li\u003e\n\u003cli\u003e1 x Proximitor I\/O Module with Internal Terminations (Part Number 125680-01)\u003c\/li\u003e\n\u003cli\u003e1 x 3500\/40M Monitor User Guide (Document 143488)\u003c\/li\u003e\n\u003cli\u003e1 x 8-pin Euro-style Internal I\/O Connector Header\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Allocation\u003c\/strong\u003e: Install the main monitor module in any available front slot to the right of the Transient Data Interface (TDI), and position the corresponding I\/O module in the rear slot directly aligned with the main board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding and Grounding\u003c\/strong\u003e: Terminate all coaxial signal cable shields at the designated chassis ground studs to prevent electromagnetic interference and maintain measurement integrity for buffered outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Compatibility Check\u003c\/strong\u003e: Ensure the 3500 rack utilizes software revision 2.50 or later for 3500\/01, version 2.20 or later for 3500\/02, and version 1.21 or later for 3500\/03 prior to powering on the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many proximity transducer channels does the 3500\/40M monitor accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts input signals from 1 to 4 proximity transducers depending on channel configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical power consumption of the 3500\/40M monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe typical power consumption is 7.7 watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage is supplied to power the connected proximity transducers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides a regulated transducer power supply of -24 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the input impedance of the standard I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard I\/O input impedance for proximitor and acceleration inputs is 10 kΩ.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are buffered transducer signals accessed on the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFront-panel coaxial connectors provide short-circuit protected buffered transducer outputs for each active channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output impedance of the buffered transducer outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output impedance of the buffered transducer outputs is 550 Ω.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3500\/40M monitor operate in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen used with appropriate I\/O options, the module supports Class I, Division 2 and Zone 2 hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software version is required to operate the 3500\/40M monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 3500\/01 software version 2.50 or later, 3500\/02 version 2.20 or later, and 3500\/03 version 1.21 or later.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46892230508717,"sku":"3500\/40-01-R0","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350040M-14_80c2a94e-4abc-4c17-8008-45afe227415f.jpg?v=1784770043","url":"https:\/\/www.maxwellplc.com\/ga\/products\/3500-40-01-r0-bently-nevada-proximitor-monitor-3500-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}