{"product_id":"33101-00-22-10-02-05-bently-nevada-3300-system-11-mm-proximity-transducer","title":"33101-00-22-10-02-05 Bently Nevada 3300 System 11 mm Proximity Transducer","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in machinery condition monitoring platforms, the \u003cstrong\u003eBently Nevada 33101-00-22-10-02-05\u003c\/strong\u003e (\u003cstrong\u003e33101\u003c\/strong\u003e 11 mm Proximity Transducer) provides direct physical-to-electrical execution by converting the proximity gap into relative voltage changes.\u003c\/p\u003e\n\u003ch3\u003eOptions and Part Number Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e33101\u003c\/strong\u003e: Base product catalog code for the 3300 XL 11 mm proximity probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e22\u003c\/strong\u003e: Overall case length option configured for 22 feet of total system length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Thread size configuration defining a 3\/8-24 UNF-2A mechanical interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Hardware adjustment option indicating standard configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Agency approval option selecting integrated CSA, ATEX, and IECEx certifications for explosion-proof installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e33101-00-22-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.4 cm x 22.2 cm x 3.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e22 feet (approx. 6.7 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4.0 mm (160 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/micrometer (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +100 deg C (-60 to +212 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor, driven by external Proximitor power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm transducer utilizes eddy-current probe scaling to monitor massive industrial rotor dynamics. Operating on high-frequency RF fields, the probe tip measures the distance to a conductive target without physical contact. Field setup routines rely on gap voltage validation (-10 VDC targets) benchmarks to anchor the operational midpoint within the 4.0 mm linear tracking envelope. The system incorporates passive cross-talk suppression to isolate nearby sensors, allowing precise radial vibration and axial position measurement on high-speed fluid-film bearing machinery.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 33101-00-22-10-02-05 11 mm Proximity Transducer Probe\u003c\/li\u003e\n\u003cli\u003e1 x Integrated Coaxial Connector Protective Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eMechanical Mounting and Case Torque\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the probe body into the machine casing using the 3\/8-24 UNF-2A threads, avoiding tight kinks in the integrated 22-foot cable lead.\u003c\/li\u003e\n\u003cli\u003eApply a maximum mounting torque of 11.3 N-m (100 in-lb) to the locknuts to prevent stripping or mechanical strain on the internal transducer elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Integrity and Connector Insulation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the coaxial ClickLoc connectors are clear of oil and grease before snapping them together with the extension cable.\u003c\/li\u003e\n\u003cli\u003eWrap the field connection point with silicone self-fusing tape or install a dedicated connector sleeve to prevent grounding faults caused by contact with the junction box wall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Clarifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the baseline gap voltage validation (-10 VDC target) verified during physical installation?\u003c\/p\u003e\n\u003cp\u003eTechnicians adjust the probe depth while tracking the DC voltage at the Proximitor output until it measures -10 VDC, indicating the absolute center of the linear calibration scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operational risk occurs if the transducer cable exceeds the specified bend radius?\u003c\/p\u003e\n\u003cp\u003eBending sharper than a 25.4 mm (1.0 inch) radius introduces structural impedance anomalies in the coaxial line, causing calibration drift and signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe support direct hot-swap extraction from an active monitoring loop?\u003c\/p\u003e\n\u003cp\u003eYes, the sensor can be physically uninstalled while active, but monitoring channels must be bypassed beforehand to prevent triggering false trip sequences on the machinery safety monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptoms indicate a loss of cross-talk suppression between two adjacent probes?\u003c\/p\u003e\n\u003cp\u003eProbes mounted closer than 40 mm apart without isolation generate a high-frequency beating interference, which skews dynamic vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 11 mm probe tip withstand constant submersion in industrial lubricating oil?\u003c\/p\u003e\n\u003cp\u003eYes, the polyphenylene sulfide (PPS) tip material provides an absolute chemical barrier against petroleum-based lubricants and synthetic compressor fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does extreme temperature cycling down to -51 deg C affect the scale factor stability?\u003c\/p\u003e\n\u003cp\u003eThe internal compensation loop keeps scale factor variances below 10% across the full temperature range, guaranteeing stable performance in unheated outdoor stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat problem occurs if the probe faces a non-ferrous target like aluminum instead of 4140 steel?\u003c\/p\u003e\n\u003cp\u003eNon-magnetic targets alter the eddy-current probe scaling, resulting in a compressed linear envelope and a severe drop in nominal output voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy must the probe case be electrically isolated from the instrument rack ground plane?\u003c\/p\u003e\n\u003cp\u003eIsolating the case prevents stray industrial ground loops from flowing through the sensitive coaxial shield line, ensuring clean signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026693542061,"sku":"33101-00-22-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian11_4a07e979-e3de-4d12-9fff-9b8006a2088e.jpg?v=1783994816","url":"https:\/\/www.maxwellplc.com\/ga\/products\/33101-00-22-10-02-05-bently-nevada-3300-system-11-mm-proximity-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}