{"product_id":"330905-00-07-10-12-cn-bently-nevada-3300-nsv-series-proximity-probes","title":"330905-00-07-10-12-CN Bently Nevada 3300 NSv Series Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330905-00-07-10-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330905\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute physical displacement tracking and micro-gap shaft vibration detection across 3300 System platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Option Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330905\u003c\/strong\u003e: Base 3300 NSv proximity probe configuration with M10X1 metric thread and unarmored cable profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: 0 mm minimum unthreaded length mechanical specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: 70 mm minimum overall case length physical dimension.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: 1.0 meter (39 inches) nominal total cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Integrated miniature coaxial ClickLoc connector and fluid-sealed FluidLoc cable architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Region-specific standard designation variant identifier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters Table\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330905-00-07-10-12-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 x 22 x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-34 to +177 deg C (Probe tip and cable element)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDriven by external Proximitor loop at 17.5 VDC to 26 VDC, 12 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10X1 metric thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (39 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc sealed process moisture barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Conditioning and Signal Calibration\u003c\/h3\u003e\n\u003cp\u003eThe physical interface operates under specialized eddy-current probe scaling metrics optimized for tight mounting spaces and small target profiles. Setting the physical mounting position requires checking the gap voltage validation (-10 VDC targets) within the Proximitor loop before recording dynamic machinery shifts. This internal tuning tracks high-frequency rotor dynamics with accuracy, while the specialized FluidLoc cable configuration blocks process liquids from creeping into the core element, preserving cross-talk suppression paths across close-proximity sensor clusters.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330905-00-07-10-12-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Interface Protection Sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Assembly and Mechanical Routing Guidelines\u003c\/h3\u003e\n\u003ch3\u003eThreaded Casing Insertion\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the M10X1 probe body manually into the machined casing port, tracking structural clearances across the 70 mm case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten the primary locknut using calibrated torque limits to protect the internal unarmored coaxial junction from shearing forces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCoaxial Routing and Lock Engagement\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the miniature coaxial ClickLoc connector directly to the matching extension cable terminal until the lock snaps shut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the FluidLoc cable along dedicated metal trays to isolate the dynamic signal from surrounding high-current power conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific 3300 NSv probe support toolless hot-swapping while the monitor channel is active?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap maneuvers are completely restricted; isolate the external loop excitation power before uncoupling or connecting the coaxial line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical parameters dictate the structural shape of the 00-07 suffix configuration?\u003c\/p\u003e\n\u003cp\u003eThe 00-07 options specify a 0 mm unthreaded section combined with a 70 mm total machined case length on an M10X1 thread pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal FluidLoc cable shield the system from fluid intrusion?\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc design features internal physical blocks that seal the core wires, preventing oils or coolants from leaking through the cable jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat total hardware weight and dimension metrics apply to shipment manifests?\u003c\/p\u003e\n\u003cp\u003eThe unboxed probe has a net mass profile of 0.14 kg inside standard package space parameters measuring 20.3 x 22 x 3.5 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy must engineers track gap voltage validation (-10 VDC targets) during mechanical positioning?\u003c\/p\u003e\n\u003cp\u003eThe -10 VDC point aligns the probe tip at the exact center of its linear range, ensuring balanced negative and positive vibration signal capture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific unarmored part number configuration feature stainless steel protective armor?\u003c\/p\u003e\n\u003cp\u003eNo, this suffix string defines an unarmored cable variant, requiring external conduit runs if mechanical routing risks are present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat standard factory tolerance limits restrict the nominal 1.0 meter total length option?\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter total cable length adheres to standard factory bounds of +0.25 meters maximum and -0.10 meters minimum variance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do closely grouped M10 proximity probes preserve signal integrity against structural cross-talk?\u003c\/p\u003e\n\u003cp\u003eThe integrated outer shielding layer links directly to system ground at the Proximitor casing, enforcing cross-talk suppression between channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026846929069,"sku":"330905-00-07-10-12-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_aa27406f-8da9-4cef-9723-d9f0f9b975d7.jpg?v=1782721851","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330905-00-07-10-12-cn-bently-nevada-3300-nsv-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}