{"product_id":"330904-04-14-10-12-05-bently-nevada-3300-nsv-series-proximity-probe","title":"330904-04-14-10-12-05 Bently Nevada 3300 NSv Series Proximity Probe","description":"\u003cp\u003eConfigured for proximity sensing in constrained spatial envelopes, the \u003cstrong\u003eBently Nevada 330904-04-14-10-12-05\u003c\/strong\u003e (\u003cstrong\u003e330904-04-14-10-12-05\u003c\/strong\u003e Proximity Probe) provides direct physical signal acquisition for eddy-current monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330904: Base Model (3300 NSv Proximity Probe)\u003c\/li\u003e\n\u003cli\u003e04: M8 x 1 thread configuration\u003c\/li\u003e\n\u003cli\u003e14: Unthreaded length designator\u003c\/li\u003e\n\u003cli\u003e10: 1.0 meter (39 in) system length\u003c\/li\u003e\n\u003cli\u003e12: Miniature coaxial ClickLoc connector type\u003c\/li\u003e\n\u003cli\u003e05: Multiple agency approvals (includes FluidLoc cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330904-04-14-10-12-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.3 x 22 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered by Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread\u003c\/td\u003e\n\u003ctd\u003eM8 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv probe utilizes eddy-current probe scaling specifically engineered for small-diameter shafts or limited-access applications. During system commissioning, gap voltage validation against -10 VDC targets is necessary to ensure the linear range is centered relative to the observed shaft motion. Proper cross-talk suppression is achieved through the integration of the probe and matched extension cable, preventing signal interference when multiple transducers are positioned in high-density arrays. Consistent rotor dynamics data is maintained through the use of the proprietary ClickLoc connection interface, which ensures stable impedance across the transducer loop.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330904-04-14-10-12-05 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Installation and Technical Reference documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Torque: Utilize appropriate wrench flats on the probe body; do not exceed manufacturer-specified torque limits to prevent casing deformation.\u003c\/li\u003e\n\u003cli\u003eConnector Handling: The ClickLoc connector is designed for secure retention; ensure the locking mechanism is fully engaged to maintain a low-impedance signal path.\u003c\/li\u003e\n\u003cli\u003eCable Protection: The FluidLoc cable provides resistance to environmental contamination; route cables to avoid mechanical abrasion and sharp bends.\u003c\/li\u003e\n\u003cli\u003eGap Setting: Adjust the probe-to-target distance using a feeler gauge or depth micrometer to reach the nominal -10 VDC gap voltage target.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the advantage of the NSv design?\u003c\/p\u003e\n\u003cp\u003eThe NSv (Near-field) series is optimized for smaller shafts or close-clearance applications where standard 3300 XL probes lack sufficient linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the probe cable?\u003c\/p\u003e\n\u003cp\u003eNo, the system is factory-calibrated as a complete assembly. Altering the cable length will invalidate the calibration and scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector waterproof?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is environmentally sealed for typical industrial machine environments, but not intended for continuous submersion in pressurized fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the probe is functioning?\u003c\/p\u003e\n\u003cp\u003eMonitor the DC gap voltage at the Proximitor output. A voltage outside the typical operating range indicates an open loop, short circuit, or extreme probe gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific Proximitor?\u003c\/p\u003e\n\u003cp\u003eYes, it must be paired with a compatible 3300 NSv Proximitor sensor calibrated to the same system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the armor?\u003c\/p\u003e\n\u003cp\u003eThe armor provides mechanical protection against debris, vibration-induced wear, and accidental damage in harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous areas?\u003c\/p\u003e\n\u003cp\u003eThe -05 suffix indicates multiple agency approvals; verify the specific hazardous area classification ratings in the product manual before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does FluidLoc cable function?\u003c\/p\u003e\n\u003cp\u003eFluidLoc construction prevents oil and other process fluids from migrating through the cable jacket and into the connector or sensor head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026793255085,"sku":"330904-04-14-10-12-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian_2_77cc9133-fc89-4039-af3d-537bd1875e7e.jpg?v=1783404652","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330904-04-14-10-12-05-bently-nevada-3300-nsv-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}