{"product_id":"330904-00-25-05-02-cn-bently-nevada-3300-xl-nsv-proximity-probes","title":"330904-00-25-05-02-CN Bently Nevada 3300 XL NSv Proximity Probes","description":"\u003cp\u003eConfigured for high-frequency vibration and displacement tracking in limited spatial layouts, the \u003cstrong\u003eBently Nevada 330904-00-25-05-02-CN\u003c\/strong\u003e (\u003cstrong\u003e330904-00-25-05-02-CN\u003c\/strong\u003e Proximity Probe) provides direct physical signal acquisition across industrial machinery monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix And Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Architecture: 330904 - 3300 NSv Probe (M8x1 thread)\u003c\/li\u003e\n\u003cli\u003eUnthreaded Length Option: 00 - Minimum unthreaded length (0 mm)\u003c\/li\u003e\n\u003cli\u003eOverall Case Length Option: 25 - Maximum length (250 mm)\u003c\/li\u003e\n\u003cli\u003eTotal Length Option: 05 - 0.5 meter (20 in)\u003c\/li\u003e\n\u003cli\u003eConnector and Cable Option: 02 - Miniature coaxial ClickLoc connector, standard cable\u003c\/li\u003e\n\u003cli\u003eAgency Approval Option: CN - Multiple Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330904-00-25-05-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.3 x 1.1 x 65 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive inductive sensor (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003eM8x1 thread connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics And Eddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe transducer assembly utilizes eddy-current probe scaling to map physical air gap clearances into proportional analog voltage signals. Proper system operation mandates strict gap voltage validation targeting a nominal center point between -9 VDC and -11 VDC. Rotor dynamics analysis relies on this high-frequency response to track displacement and vibration, supported by matched impedance cabling and cross-talk suppression to maintain signal fidelity across industrial monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330904-00-25-05-02-CN 3300 NSv Proximity Probe Assembly (M8x1 thread, 250 mm case length, 0.5 meter standard cable, miniature coaxial ClickLoc connector)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread Engagement: Screw the M8x1 probe housing carefully into the machinery mounting port, utilizing proper thread engagement to avoid mechanical binding.\u003c\/li\u003e\n\u003cli\u003eGap Voltage Verification: Calibrate the physical air gap clearance until the connected monitor registers a static gap voltage between -9 VDC and -11 VDC.\u003c\/li\u003e\n\u003cli\u003eLead Routing: Route the coaxial cable away from high-voltage power conduits and alternating current lines to prevent induced electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eConnector Locking: Engage the miniature coaxial ClickLoc connector fully until a positive latching action secures the connection against vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 330904-00-25-05-02-CN assembly?\u003c\/p\u003e\n\u003cp\u003eIt serves as a specialized proximity probe designed to detect shaft vibration and radial position in restricted installation spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thread standard is utilized on the probe housing?\u003c\/p\u003e\n\u003cp\u003eThe unit features an M8x1 mounting thread configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sensor require an external power supply?\u003c\/p\u003e\n\u003cp\u003eNo, it operates as a passive inductive component energized exclusively by its paired Proximitor sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total length of the integrated cable?\u003c\/p\u003e\n\u003cp\u003eThis configuration includes a total cable length of 0.5 meter (20 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the overall case length specified for this model?\u003c\/p\u003e\n\u003cp\u003eIt features an extended case length option of 250 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal operating limits govern the operational envelope?\u003c\/p\u003e\n\u003cp\u003eThe structural assembly functions reliably across a temperature range from -51 deg C up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat connector type is attached to the cable end?\u003c\/p\u003e\n\u003cp\u003eIt uses a miniature coaxial ClickLoc connector designed to prevent loosening under high vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is gap voltage validation necessary during installation?\u003c\/p\u003e\n\u003cp\u003eIt ensures the probe operates within its linear measurement range, typically centered between -9 VDC and -11 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025930604717,"sku":"330904-00-25-05-02-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian9_a207e318-27e8-4f26-b643-48793d0df67a.jpg?v=1783668726","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330904-00-25-05-02-cn-bently-nevada-3300-xl-nsv-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}