{"product_id":"330903-00-02-10-02-00-bently-nevada-proximity-probes-3300-nsv-proximity-probes","title":"330903-00-02-10-02-00 Bently Nevada Proximity Probes 3300 NSv Proximity Probes","description":"\u003cp\u003eConfigured for shaft vibration and radial displacement measurement within machinery monitoring infrastructure, the \u003cstrong\u003eBently Nevada 330903-00-02-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330903-00-02-10-02-00\u003c\/strong\u003e Proximity Probes) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330903: 3300 NSv Probe core catalog listing\u003c\/li\u003e\n\u003cli\u003e00: Unthreaded Length Option (0 mm)\u003c\/li\u003e\n\u003cli\u003e02: Overall Case Length Option (20 mm)\u003c\/li\u003e\n\u003cli\u003e10: Total Length Option (1.0 meter \/ 39 in)\u003c\/li\u003e\n\u003cli\u003e02: Connector and Cable-Type Option (Miniature coaxial ClickLoc connector standard cable)\u003c\/li\u003e\n\u003cli\u003e00: Agency Approval Option (Not required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330903-00-02-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.3 x 1.1 x 65 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003eM8 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on Proximitor power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe transducer system incorporates precise eddy-current probe scaling to translate high-frequency magnetic field variations into linear voltage outputs.\u003c\/li\u003e\n\u003cli\u003eExecutes gap voltage validation to maintain a stable nominal -10 VDC static operating point during zero-speed calibration sequences.\u003c\/li\u003e\n\u003cli\u003eCaptures high-frequency rotor dynamics and minute radial displacement signatures where standard proximity probes experience linearity compression.\u003c\/li\u003e\n\u003cli\u003eEmploys specialized signal conditioning and shielded coaxial cabling to ensure robust cross-talk suppression in confined machinery enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330903-00-02-10-02-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Miniature Coaxial ClickLoc Dust Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the M8 x 1 mounting hole is tapped cleanly perpendicular to the target shaft surface to avoid mechanical binding or angular misalignment.\u003c\/li\u003e\n\u003cli\u003eApply correct torque values matching standard M8 thread engagement guidelines to secure the probe body without inducing tip distortion.\u003c\/li\u003e\n\u003cli\u003eRoute the miniature coaxial cable away from high-voltage alternating current lines and variable frequency drives to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain clean connection interfaces at the ClickLoc terminal to preserve low-resistance grounding and signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary purpose of the 330903-00-02-10-02-00 probe?\u003c\/p\u003e\n\u003cp\u003eIt is engineered to measure radial vibration and axial position on machinery with constrained target areas or specialized shaft designs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is an NSv designation used instead of standard 3300 XL models?\u003c\/p\u003e\n\u003cp\u003eThe NSv configuration utilizes altered high-frequency modulation circuitry to support smaller target sizes and shorter linear measurement ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal static operating gap voltage?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated to produce a nominal -10 VDC output at the designated mechanical operating gap position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan standard 3300 XL extension cables be used with this NSv probe?\u003c\/p\u003e\n\u003cp\u003eNo, NSv probes require impedance-matched extension cables and monitors specifically tailored to the NSv circuit architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thread profile does the probe housing feature?\u003c\/p\u003e\n\u003cp\u003eThe probe utilizes an M8 x 1 external thread profile across its 20 mm overall case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat temperature range is permissible for continuous operation?\u003c\/p\u003e\n\u003cp\u003eThe probe tip and cable assembly function reliably within an ambient temperature span from -51 deg C to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the ClickLoc connector secure the cable connection?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc design provides a secure mechanical lock that resists vibration loosening without requiring specialized torque wrenches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions apply to cable routing near power sources?\u003c\/p\u003e\n\u003cp\u003eCoaxial cables must be routed in dedicated metallic conduits separated from heavy power circuits to suppress electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025674031277,"sku":"330903-00-02-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-57_dfe424d3-a96a-4bcd-9edd-22779ea38a86.jpg?v=1783668656","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330903-00-02-10-02-00-bently-nevada-proximity-probes-3300-nsv-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}