{"product_id":"330901-00-90-10-02-cn-bently-nevada-proximity-probes-3300-xl-nsv","title":"330901-00-90-10-02-CN Bently Nevada Proximity Probes 3300 XL NSv","description":"\u003cp\u003eConfigured for high-precision radial vibration and axial position telemetry in tight physical envelopes, the \u003cstrong\u003eBently Nevada 330901-00-90-10-02-CN\u003c\/strong\u003e (\u003cstrong\u003e330901-00-90-10-02-CN\u003c\/strong\u003e 3300 NSv Proximity Probes) provides direct physical execution for non-contact eddy-current measurement frameworks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Architecture Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: 330901 (3300 NSv Unarmored Probe)\u003c\/li\u003e\n\u003cli\u003eUnthreaded Length: 00 (0.0 in unthreaded section)\u003c\/li\u003e\n\u003cli\u003eCase Length: 90 (9.0 in overall case length)\u003c\/li\u003e\n\u003cli\u003eCable Length: 10 (1.0 meter \/ 39 in integrated lead)\u003c\/li\u003e\n\u003cli\u003eConnector Type: 02 (Miniature coaxial ClickLoc configuration)\u003c\/li\u003e\n\u003cli\u003eAgency Approval: CN (Multiple Approvals)\u003c\/li\u003e\n\u003cli\u003eSystem Architecture: Bently Nevada 3300 XL NSv\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330901-00-90-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330901-00-90-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 1 x 120 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via Proximitor Sensor (-17.5 VDC to -26 VDC loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eNon-contact displacement and vibration signal transduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003eProximity voltage response scaled to 7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eAccurate telemetry acquisition relies on maintaining strict eddy-current probe scaling across the 1.5 mm linear operating envelope. Maintenance personnel must execute gap voltage verification at the associated Proximitor output terminals, targeting a nominal -10 VDC setpoint (within an acceptable operational window of -8 VDC to -12 VDC) to center the dynamic shaft displacement curve. Proper rotor dynamics analysis further demands effective cross-talk suppression and continuous shield grounding to isolate low-level RF signals from ambient electromagnetic interference generated by adjacent variable-frequency drives.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330901 NSv Unarmored Probe Tip Assembly (1\/4-28 UNF Thread)\u003c\/li\u003e\n\u003cli\u003e1 x 1.0 m Integrated Coaxial Cable with ClickLoc Connection\u003c\/li\u003e\n\u003cli\u003e1 x Factory Calibration and Compliance Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread Preparation: Drill and tap the machinery casing for a 1\/4-28 UNF threaded body, maintaining strict perpendicularity to the monitored shaft surface.\u003c\/li\u003e\n\u003cli\u003eTorque Specifications: Secure the probe housing using a calibrated torque wrench to recommended manufacturer limits, avoiding over-tightening.\u003c\/li\u003e\n\u003cli\u003eAir Gap Alignment: Set the initial physical gap distance to 1.0 mm (40 mils) prior to locking structural mounting hardware in place.\u003c\/li\u003e\n\u003cli\u003eConnector Handling: Tighten ClickLoc coaxial connectors by hand only; never use pliers or mechanical tools to prevent thread and pin damage.\u003c\/li\u003e\n\u003cli\u003eGrounding Requirements: Ensure proper earthing of shield wiring, particularly for CN-approved units deployed in hazardous locations to mitigate electrostatic charge accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhy does the NSv series utilize a shorter linear range than standard 8 mm probes?\u003c\/p\u003e\n\u003cp\u003eThe NSv employs specialized electromagnetic field shaping designed specifically for small targets and tight counterbores, resulting in a 1.5 mm linear span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe operate independently without a Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eNo, it requires an external 3300 XL NSv Proximitor sensor to provide high-frequency radio-frequency excitation and convert impedance changes into voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage falls outside the -8 VDC to -12 VDC window?\u003c\/p\u003e\n\u003cp\u003eOperating outside this range risks driving the measurement circuit into non-linear regions, causing signal distortion during peak vibration events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre connector protectors required for indoor installations?\u003c\/p\u003e\n\u003cp\u003eYes, connector protectors prevent microscopic moisture accumulation and oil migration from contaminating the gold-plated ClickLoc mating surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it permissible to cut or splice the integrated coaxial cable?\u003c\/p\u003e\n\u003cp\u003eNo, altering cable length changes total system capacitance and invalidates factory calibration, requiring matched component replacements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical damage compromises probe performance?\u003c\/p\u003e\n\u003cp\u003eScratches, gouges, or thermal degradation of the polyphenylene sulfide probe tip material alter the eddy-current field and corrupt output linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this part support live hot-swapping during machine operation?\u003c\/p\u003e\n\u003cp\u003eLive replacement is prohibited because disconnecting energized monitoring circuits induces electrical transients that trigger false machinery protection trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable cable run between the Proximitor sensor and the monitor?\u003c\/p\u003e\n\u003cp\u003eThe maximum distance between the Proximitor sensor and the monitor rack is 305 meters (1,000 feet) using three-conductor shielded triad cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025335963821,"sku":"330901-00-90-10-02-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--4_02abaf48-4538-4f62-bb3f-6a71a38fed4f.jpg?v=1783668562","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330901-00-90-10-02-cn-bently-nevada-proximity-probes-3300-xl-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}