{"product_id":"330881-16-00-180-03-02-bently-nevada-3300-xl-series-proxpac-xl-proximity-transducer","title":"330881-16-00-180-03-02 Bently Nevada 3300 XL Series PROXPAC XL Proximity Transducer","description":"\u003cp\u003eConfigured for high-precision vibration and position monitoring in industrial rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-00-180-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROXPAC XL Proximity Transducer) provides direct physical signal execution via an integrated 8 mm eddy-current probe assembly.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Suffix Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model number identifies the following mechanical and interface parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881: PROXPAC XL transducer assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16: Housing material and mounting configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Standoff adapter configuration (None)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e180: Probe length (180 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Agency approval and certification code\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Interface and connector configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-00-180-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.50 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 cm x 15 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66 \/ Type 4X\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eSystem accuracy is contingent upon rigorous eddy-current probe scaling protocols. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassembly requires calibration against the target shaft material to ensure linear output. Field technicians must validate the system gap voltage, targeting a nominal -10 VDC at the linear range midpoint to optimize signal range. Cross-talk suppression is maintained by ensuring adequate spatial separation of the probe tip from other electromagnetic sources and metallic structures, thereby ensuring reliable rotor dynamics data extraction during transient and steady-state machine operation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330881-16-00-180-03-02 PROXPAC XL Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Conduit entry plugs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Installation washers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation and mounting manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStructural Mounting: Ensure the transducer is mounted to a rigid machine surface; minimize mechanical resonance between the housing and the frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThreaded Interface: Use caution when tightening the probe threads; adhere to specified torque limits to avoid internal housing deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer housing to the machine earth ground to facilitate electrostatic charge dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Sealing: Confirm that all conduit entries are sealed with the provided plugs to maintain the IP66 ingress protection rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 8 mm probe tip be removed? No, the probe assembly is factory-integrated and sealed within the PROXPAC XL housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the housing material conductive? Yes, it is designed for effective electrostatic charge dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the linear range of this transducer? The system is designed for a 2.0 mm linear operating range typical of 3300 XL 8 mm probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a faulty transducer? A \"Not OK\" status on the monitor rack, typically indicated by a voltage at the power supply limit, indicates a probe or cable failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this be used in explosive environments? Verification of the agency approval code is required; ensure the site classification matches the transducer rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the housing compatible with existing conduit systems? Yes, it is designed to interface with standard industrial conduit and cable glands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat effect does thermal expansion have? Probe position must account for machine casing expansion to keep the probe within its linear gap range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there torque limits for the mounting hardware? Follow the provided installation manual for torque specifications to ensure a secure, distortion-free mount.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518838562989,"sku":"330881-16-00-180-03-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-00-180-03-02-proxpac-xl-proximity-transducer-wylro5d5ipe.jpg?v=1766980130","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330881-16-00-180-03-02-bently-nevada-3300-xl-series-proxpac-xl-proximity-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}