{"product_id":"330851-02-000-066-10-00-00-bently-nevada-3300-xl-proximity-probe","title":"330851-02-000-066-10-00-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting displacement sensing tasks in turbomachinery train monitoring loops, the \u003cstrong\u003eBently Nevada 330851-02-000-066-10-00-00\u003c\/strong\u003e (\u003cstrong\u003e330851-02-000-066-10-00-00\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution of eddy-current gap variations.\u003c\/p\u003e\n\u003ch3\u003eOption Structure \u0026amp; Code Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330851\u003c\/strong\u003e: Core designator for the 3300 XL 25 mm proximity probe hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Specifies an M30x2 threaded case geometric outline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000\u003c\/strong\u003e: Indicates a 0.0 in unthreaded length variable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e066\u003c\/strong\u003e: Denotes a 0.6 in total overall case length parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Sets the physical electrical cable length to exactly 1.0 metre (3.3 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Confirms a fluid-tight plain cable structure with no external armor cladding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Restricts safety categorization options to standard no approvals configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Dimensions\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-066-10-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.5 x 22.5 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C nominal sensor range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer element powered by external Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Profile\u003c\/td\u003e\n\u003ctd\u003eM30x2 threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e0.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Total Length\u003c\/td\u003e\n\u003ctd\u003e1.0 metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Scaling \u0026amp; Rotor Dynamics Validation\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm coil assembly relies on precise eddy-current probe scaling matrices to accurately translate physical gap voltage changes into micro-inch metrics. During high-amplitude rotor dynamics excursions, the continuous linear response slope feeds directly into proximity sensor channels to ensure valid tracking without cross-talk suppression failures near local journal bearing housings.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330851-02-000-066-10-00-00 3300 XL 25 mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Coaxial Connector Protection Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting \u0026amp; Mechanical Alignment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBracket Torque \u0026amp; Thread Indexing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M30 case systematically into the target mounting bracket using standard mechanical steps.\u003c\/li\u003e\n\u003cli\u003eAvoid tight twisting profiles on the output coaxial pig-tail line while adjusting the insertion position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Cable Routing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the 1.0 metre signal extension line inside matching metallic conduit runs to prevent mechanical chafing.\u003c\/li\u003e\n\u003cli\u003eKeep minimum bend radii parameters above 25.4 mm (1.0 in) along all physical junction paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer Infrastructure FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage indication value during a standard static calibration loop?\u003c\/p\u003e\n\u003cp\u003eThe industrial benchmark targets a standard nominal -10 VDC gap voltage level at the geometric center of the linear calibration span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific unarmored coaxial cable variant be deployed inside fluid-splash areas?\u003c\/p\u003e\n\u003cp\u003eYes, the outer polymer jacket resists standard synthetic machine lubricating oils, but open physical crushing forces must be avoided.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the internal field terminal links protected from shorting against surrounding metal machinery frames?\u003c\/p\u003e\n\u003cp\u003eThe probe connector terminal must be fully insulated using the enclosed clear sleeve kits to isolate the outer signal shield loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat behavior occurs if the target rotor moves completely past the physical calibration range?\u003c\/p\u003e\n\u003cp\u003eThe output electrical link saturates toward upper limit voltages, which triggers a transducer limit flag inside the tracking monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this 25 mm transducer system share identical extension cables with smaller 8 mm probe setups?\u003c\/p\u003e\n\u003cp\u003eNo, the 25 mm transducer structure uses dedicated matching networks that cannot be paired with 8 mm component configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanical thread engagement step is needed to lock the case into a blind machine port safely?\u003c\/p\u003e\n\u003cp\u003eThe mounting sequence requires a minimum of 5 full thread engagements to ensure structural stability against continuous mechanical vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs a separate calibration adjustment needed if the target shaft alloy changes from 4140 steel?\u003c\/p\u003e\n\u003cp\u003eYes, changes in target chemistry modify the eddy-current probe scaling performance, requiring customized instrument adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum continuous storage temperature limit allowed for this unpowered hardware?\u003c\/p\u003e\n\u003cp\u003eThe passive hardware elements maintain physical layout stability across storage ranges from -51 to +177 deg C without damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026686496941,"sku":"330851-02-000-066-10-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--4_827c014a-ffa5-45f0-a576-486efdfe0943.jpg?v=1783666025","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330851-02-000-066-10-00-00-bently-nevada-3300-xl-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}