{"product_id":"330851-02-000-050-90-00-05-bently-nevada-3300-xl-series-proximity-probe","title":"330851-02-000-050-90-00-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-000-050-90-00-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting dynamic and static displacement measurements within 3300 XL 25 mm Proximity Transducer platforms. The hardware tracks proximity variations by generating high-frequency eddy currents at the sensor tip, providing raw physical voltage inputs corresponding to the gap distance changes of the monitored shaft target.\u003c\/p\u003e\n\u003ch3\u003eStructural Option Codes Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: Main catalog base identifier for the 3300 XL 25 mm proximity probe hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Case thread type option denoting an M30x2 metric thread profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded length specification indicating 0 mm of unthreaded smooth casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e050: Overall case length specification indicating a 50 mm total housing shell.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90: Total system length option selecting a 9.0 meters (29.5 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Armor option indicating no flexible stainless steel conduit armor over the outer jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval specification establishing certification under multiple international hazardous area standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-050-90-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Tip Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM30x2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor element powered via external Proximitor excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 22.5 cm x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm transducer layout employs precise eddy-current probe scaling configurations optimized for large-scale shaft movement tracking and machinery rotor dynamics. During baseline machine commissioning calibration, the system maps output data against a predefined gap voltage validation curve targeting specific negative VDC indicators. Built-in internal cross-talk suppression paths insulate the core high-frequency transmission coil from neighboring instrumentation arrays, maintaining clean physical signals in tight bearing block structures.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330851-02-000-050-90-00-05 Proximity Transducer Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Protection End Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Threading and Case Alignment\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the M30x2 probe housing directly into the calibrated bracketry, verifying a minimum mechanical thread engagement depth of 5 full threads before final locking torque is applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotate the sensor shaft inside the mount while monitoring live DC output potential until the designated operational clearance target is locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePhysical Cable Routing and Shield Termination\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFasten the 9.0 meters non-armored lead wire along protective routing channels using non-conductive, padded tie wraps spaced to prevent friction insulation wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the extension cables clear of power lines to block high-voltage interference fields inside the cabinet framework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this 25 mm proximity sensor support dynamic replacement while the host TSI rack is energized?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware allows technicians to disconnect or swap out individual sensor nodes without generating faults in adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the baseline gap voltage validation standard executed at the installation site?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the raw negative DC potential at the monitor proxy port to calibrate the core resting position of the shaft.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat parameters define the active eddy-current probe scaling performance for this 25 mm model?\u003c\/p\u003e\n\u003cp\u003eThe wide 25 mm tip face dictates a broader magnetic field footprint, expanding the maximum linear measuring path over standard smaller tips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe element run natively without an active Proximitor processing module?\u003c\/p\u003e\n\u003cp\u003eNo, this device is an unpowered inductive sensor that relies entirely on high-frequency driver loops supplied by a paired Proximitor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical step protects the sensor lines from cross-talk suppression failures when grouped?\u003c\/p\u003e\n\u003cp\u003eProbes must be physically separated by standard radial distance limits to prevent overlapping fields from bleeding across conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of electrical terminator is fitted to the tail of the 9.0 meters cable?\u003c\/p\u003e\n\u003cp\u003eThe integrated line ends in a miniature coaxial click-loc push-lock connector designed to interface with matching extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the non-armored option change the operating temperature thresholds of the probe jacket?\u003c\/p\u003e\n\u003cp\u003eNo, the omission of steel armor lowers the total structural weight but retains the standard physical operational bounds up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is structural shield grounding handled for the integrated transducer lines?\u003c\/p\u003e\n\u003cp\u003eThe outer braided shield must connect to a clean instrumentation ground block inside the junction box while leaving the probe body isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026767433901,"sku":"330851-02-000-050-90-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-59_7930bb3a-62a4-42db-87c5-f0936cd98648.jpg?v=1783666001","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330851-02-000-050-90-00-05-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}