{"product_id":"330195-02-12-10-00-bently-nevada-proximity-probes-3300-xl","title":"330195-02-12-10-00 Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eConfigured for shaft vibration and position measurement within machinery protection frameworks, the \u003cstrong\u003eBently Nevada 330195-02-12-10-00\u003c\/strong\u003e (\u003cstrong\u003e330195-02-12-10-00\u003c\/strong\u003e Proximity Probes) provides direct physical and electrical execution by transforming clearance variations into proportional voltage outputs.\u003c\/p\u003e\n\u003ch3\u003eModel Code and Suffix Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330195: 3300 XL Extended Temperature Range (ETR) reverse mount probe component model\u003c\/li\u003e\n\u003cli\u003e02: 0.2 metre integral cable length option\u003c\/li\u003e\n\u003cli\u003e12: Miniature coaxial ClickLoc connector option with protection\u003c\/li\u003e\n\u003cli\u003e10: Standard mounting thread and unthreaded length specification\u003c\/li\u003e\n\u003cli\u003e00: Standard agency approval option without hazardous area classification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330195-02-12-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 15.0 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer element (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Gap Voltage Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEddy-current probe scaling translates mechanical shaft displacement relative to the probe tip directly into precise electrical signals.\u003c\/li\u003e\n\u003cli\u003eProper system calibration requires gap voltage validation to ensure the static operating point achieves the -10 VDC target within the linear range.\u003c\/li\u003e\n\u003cli\u003eRotor dynamics analysis depends on the high-frequency response of the ETR reverse mount probe configuration to track transient vibrations accurately.\u003c\/li\u003e\n\u003cli\u003eCross-talk suppression properties prevent mutual signal interference when multiple sensing channels are installed closely on machine housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330195-02-12-10-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Reverse Mount Nut Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Insulating Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the probe using the reverse mount configuration into the designated machine casing port, ensuring secure thread engagement.\u003c\/li\u003e\n\u003cli\u003eRoute the short integral coaxial cable carefully to avoid sharp bends that could compromise impedance and shielding integrity.\u003c\/li\u003e\n\u003cli\u003eProtect connector interfaces from moisture and particulate contamination during physical installation inside machinery enclosures.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield exclusively at the monitoring instrumentation rack ground to eliminate disruptive ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor for this proximity transducer model?\u003c\/p\u003e\n\u003cp\u003eThe incremental scale factor is calibrated to 7.87 V\/mm across the standard linear measuring range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating temperature range is supported by the ETR design?\u003c\/p\u003e\n\u003cp\u003eThe probe withstands extreme environmental temperatures ranging continuously from -51 deg C to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the static gap voltage be adjusted during initial setup?\u003c\/p\u003e\n\u003cp\u003eThe gap voltage must be adjusted to -10 VDC using a digital multimeter connected to the Proximitor sensor output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the integral cable length be modified or shortened on-site?\u003c\/p\u003e\n\u003cp\u003eField cutting or splicing alters electrical resonance and voids factory calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thread profile does this reverse mount probe utilize?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates a specialized thread structure engineered specifically for reverse mount installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require an independent power source?\u003c\/p\u003e\n\u003cp\u003eNo, it operates passively and receives excitation voltage through the connected Proximitor sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the linear measurement range of the 8 mm probe tip?\u003c\/p\u003e\n\u003cp\u003eThe linear measurement span covers 2.0 mm centered symmetrically along the response curve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal integrity preserved against external electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eAn outer metallic braid and robust protective fluorocarbon jacket encase the high-frequency coaxial line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025237856429,"sku":"330195-02-12-10-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-58_e99ee8f6-3923-45d1-95c5-fce2dab258a8.jpg?v=1783655965","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330195-02-12-10-00-bently-nevada-proximity-probes-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}