{"product_id":"330180-x1-05-mod-145004-66-bently-nevada-3300-xl-series-proximity-sensor","title":"330180-X1-05 MOD:145004-66 Bently Nevada 3300 XL Series Proximity Sensor","description":"\u003cp\u003eConfigured for displacement measurement, the \u003cstrong\u003eBently Nevada 330180-X1-05 MOD:145004-66\u003c\/strong\u003e (\u003cstrong\u003e330180-X1-05\u003c\/strong\u003e Proximitor Sensor) provides direct physical signal acquisition for monitoring shaft position and vibration characteristics.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330180: Base Model (3300 XL Proximitor Sensor)\u003c\/li\u003e\n\u003cli\u003eX1: System length designator (1.0m, 5.0m, or 9.0m)\u003c\/li\u003e\n\u003cli\u003e05: Agency Approval (CSA, ATEX, IECEx)\u003c\/li\u003e\n\u003cli\u003eMOD: 145004-66 factory-configured modification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05 MOD:145004-66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 3.5 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered by Proximitor loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Material\u003c\/td\u003e\n\u003ctd\u003eA308 Aluminum \/ PPS Probe Tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL Proximitor Sensor utilizes advanced eddy-current probe scaling to ensure linear response across the full measurement range. Proper gap voltage validation against -10 VDC targets is required during installation to align the transducer within the linear output region. The sensor assembly provides robust cross-talk suppression, allowing multiple probes to be installed in high-density proximity arrangements without signal degradation. Stable rotor dynamics data acquisition is maintained through integrated RFI\/EMI immunity, which permits mounting in non-metallic or fiberglass housings without degradation of signal integrity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330180-X1-05 MOD:145004-66 Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e1 x 35 mm DIN-rail mounting hardware set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Configuration: The sensor supports both 35 mm DIN-rail and 4-hole panel mounting, utilizing a footprint compatible with legacy 3300 series sensors.\u003c\/li\u003e\n\u003cli\u003eGrounding and Isolation: The mounting base provides inherent electrical isolation from the chassis, eliminating the requirement for auxiliary isolator plates.\u003c\/li\u003e\n\u003cli\u003eCable Routing: Maintain integrity of the coaxial extension cable; minimize sharp bends and secure the cable to prevent mechanical fatigue.\u003c\/li\u003e\n\u003cli\u003eSignal Shielding: The high RFI\/EMI immunity of this model allows for installation in standard cabinets without requiring dedicated metallic conduit or specialized shielding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 330180-X1-05 be replaced with older Proximitor models?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL series is backward compatible; however, ensure the total system length (probe, cable, and sensor) remains calibrated as a matched set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model require field calibration?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL system supports complete interchangeability; individual components are factory-calibrated, eliminating the need for bench-level matching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector material susceptible to oxidation?\u003c\/p\u003e\n\u003cp\u003eThe connectors utilize gold-plated brass or beryllium copper, which provides high conductivity and resistance to corrosion in typical industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of probe tip material (PPS) on temperature stability?\u003c\/p\u003e\n\u003cp\u003ePolyphenylene sulfide (PPS) offers high thermal stability and chemical resistance, supporting operation across the specified temperature range without expansion errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this sensor in hazardous area locations?\u003c\/p\u003e\n\u003cp\u003eThe -05 suffix indicates compliance with CSA, ATEX, and IECEx standards; verify zone-specific requirements in the product manual before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain RFI immunity?\u003c\/p\u003e\n\u003cp\u003eThe sensor housing and internal circuitry are designed to filter high-frequency radio interference, meeting European CE mark requirements without external shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum load resistance for the output?\u003c\/p\u003e\n\u003cp\u003eThe sensor features a 50 Ohm output resistance; ensure downstream monitoring equipment input impedance is compatible with this design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the storage temperature range different from the operating range?\u003c\/p\u003e\n\u003cp\u003eStorage temperature (-40 deg C to +85 deg C) represents the limits for hardware preservation without active excitation or process exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026788733101,"sku":"330180-X1-05 MOD:145004-66","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-X1-05_2_65e81fdb-8a05-46e7-9f0e-1b1ab9d3d986.jpg?v=1783405736","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330180-x1-05-mod-145004-66-bently-nevada-3300-xl-series-proximity-sensor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}