{"product_id":"330180-x1-05-mod-145004-64-bently-nevada-proximitor-sensor-3300-xl","title":"330180-X1-05 MOD:145004-64 Bently Nevada Proximitor Sensor 3300 XL","description":"\u003cp\u003eConfigured for shaft vibration and position measurement in machinery protection systems, the \u003cstrong\u003eBently Nevada 330180-X1-05 MOD:145004-64\u003c\/strong\u003e (\u003cstrong\u003e330180-X1-05\u003c\/strong\u003e Proximitor Sensor) provides direct physical and electrical execution by converting probe tip gap variations into proportional voltage outputs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330180: 3300 XL Proximitor Sensor component model\u003c\/li\u003e\n\u003cli\u003eX1: Total system length option (11 for 1.0 meter, 51 for 5.0 meters, 91 for 9.0 meters)\u003c\/li\u003e\n\u003cli\u003e05: CSA, ATEX, IECEx hazardous area agency approval option\u003c\/li\u003e\n\u003cli\u003eMOD:145004-64: Factory modification variant specification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05 MOD:145004-64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 cm x 2.8 cm x 6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via -17.5 VDC to -26 VDC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eA308 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation and Rotor Dynamics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProper operation requires verifying that the static gap voltage matches the -10 VDC target within the linear operating range.\u003c\/li\u003e\n\u003cli\u003eEddy-current probe scaling translates mechanical clearances directly into electrical signals for real-time rotor dynamics analysis.\u003c\/li\u003e\n\u003cli\u003eCross-talk suppression features prevent mutual electrical interference when multiple sensor channels are mounted adjacently.\u003c\/li\u003e\n\u003cli\u003eSystem interchangeability eliminates the need for individual component bench calibration or matching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330180-X1-05 MOD:145004-64 Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e1 x DIN-Mounting Hardware Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit securely onto a standard 35 mm DIN-rail or utilize the 4-hole panel mounting footprint.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor within a protective instrumentation housing or junction box to shield against harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper signal wiring separation to minimize electromagnetic interference from adjacent high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003eVerify proper terminal torque settings during field wiring to ensure reliable electrical connection under continuous vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal output resistance of this Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eThe output resistance is rated at 50 Ohm for optimal impedance matching with monitoring monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range for this sensor model?\u003c\/p\u003e\n\u003cp\u003eThe sensor operates reliably in ambient temperatures ranging from -52 deg C to +100 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sensor support backward compatibility with older systems?\u003c\/p\u003e\n\u003cp\u003eYes, it is backwards compatible with non-3300 XL series transducer system components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply voltage is required to drive the sensor?\u003c\/p\u003e\n\u003cp\u003eIt requires an input voltage supply ranging between -17.5 VDC and -26 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hazardous area certifications apply to this specific unit?\u003c\/p\u003e\n\u003cp\u003eThis unit includes CSA, ATEX, and IECEx approvals for explosive atmosphere installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan individual system components like probes and cables be interchanged?\u003c\/p\u003e\n\u003cp\u003eYes, complete interchangeability is supported without requiring manual bench calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the sensor be mounted in a standard panel configuration?\u003c\/p\u003e\n\u003cp\u003eIt features a 4-hole mounting footprint compatible with traditional panel installation layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the MOD:145004-64 designation?\u003c\/p\u003e\n\u003cp\u003eThis modification code specifies specialized factory configuration parameters for designated applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026263560365,"sku":"330180-X1-05 MOD:145004-64","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-x1-05-84_25458b5d-e8c2-4936-b07c-a8644d2707e0.jpg?v=1783663635","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330180-x1-05-mod-145004-64-bently-nevada-proximitor-sensor-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}