{"product_id":"330180-x1-05-mod-145004-13-bently-nevada-3300-xl-proximitor-sensor","title":"330180-X1-05 MOD:145004-13 Bently Nevada 3300 XL Proximitor Sensor","description":"\u003cp\u003eConfigured for high-frequency radio frequency signal excitation and signal conditioning within 3300 XL system networks, the \u003cstrong\u003eBently Nevada 330180-X1-05 MOD:145004-13\u003c\/strong\u003e (\u003cstrong\u003e330180\u003c\/strong\u003e Proximitor Sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature and Model Configurations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330180\u003c\/strong\u003e: Base catalog code designation for the 3300 XL series Proximitor sensor hardware module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eX1\u003c\/strong\u003e: System length option code denoting total calibrated loop configurations of 11 (1.0 meter), 51 (5.0 meters), or 91 (9.0 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Assigns certified CSA, ATEX, and IECEx hazardous area agency approval ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOD:145004-13\u003c\/strong\u003e: Factory modification code specifying dedicated internal filtering parameters and custom terminal tolerances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05 MOD:145004-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.7 x 2.8 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via -17.5 VDC to -26 VDC loop supply drawing less than 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-17.5 VDC to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Draw\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Tracking\u003c\/h3\u003e\n\u003cp\u003eThe Proximitor unit generates a high-frequency radio frequency carrier signal that drives the connected proximity probe, executing precise eddy-current probe scaling to map physical gap variations into linear voltage changes. This circuit conditioning loop ensures strict gap voltage validation (-10 VDC targets) during continuous rotor dynamics monitoring across rotating machinery, while preserving robust cross-talk suppression between adjacent sensor channels.\u003c\/p\u003e\n\u003ch3\u003eSupply Package Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330180-X1-05 MOD:145004-13 3300 XL Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Connection Block Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting and Mechanical Seating\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecurely snap the module onto a standard industrial DIN rail inside the protective machinery monitoring enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that chassis grounding connections between the mounting rail and enclosure backplane comply with site electromagnetic shielding requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Signal Wiring Protocols\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAttach the negative power supply lead to the designated input terminal, maintaining the supply voltage between -17.5 VDC and -26 VDC.\u003c\/li\u003e\n\u003cli\u003eRoute sensor output signal lines away from high-voltage motor power cables to prevent induced noise in the machinery protection system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat direct current supply voltage range is required to energize the Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a direct current supply voltage ranging from -17.5 VDC to -26 VDC to power internal radio frequency oscillator circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum current draw does this sensor exhibit during standard operational loops?\u003c\/p\u003e\n\u003cp\u003eThe active internal signal conditioning circuitry draws less than 12 mA under normal operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the X1 system length code determine proper hardware selection?\u003c\/p\u003e\n\u003cp\u003eThe X1 code dictates the total calibrated loop length, corresponding directly to 1.0 meter (11), 5.0 meters (51), or 9.0 meters (91) options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat nominal gap voltage target must be verified during initial static sensor calibration?\u003c\/p\u003e\n\u003cp\u003eTechnicians must validate a gap voltage target of -10 VDC at the physical center of the linear operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard typical capacitance rating for the paired extension cable?\u003c\/p\u003e\n\u003cp\u003eThe system design utilizes an extension cable capacitance profile characterized at 69.9 pF\/m (21.3 pF\/ft) typical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operational temperature range limits continuous deployment of this sensor?\u003c\/p\u003e\n\u003cp\u003eThe electronics are rated for continuous operation across an ambient temperature range spanning from -52 deg C up to +100 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific adjustment does the MOD:145004-13 designation indicate?\u003c\/p\u003e\n\u003cp\u003eThe modifier code represents a factory-engineered component or filtering revision tailored to match unique customer application requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the coaxial shield be handled to prevent ground loop interference?\u003c\/p\u003e\n\u003cp\u003eThe coaxial shield must connect to the designated common ground terminal on the module to maintain signal integrity in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026516365485,"sku":"330180-X1-05 MOD:145004-13","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-x1-05-57.jpg?v=1783657638","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330180-x1-05-mod-145004-13-bently-nevada-3300-xl-proximitor-sensor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}