{"product_id":"330130-045-02-cn-bently-nevada-extension-cables-3300-xl","title":"330130-045-02-CN Bently Nevada Extension Cables 3300 XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330130-045-02-CN is a high-reliability extension cable assembly engineered for the 3300 XL 8 mm Proximity Transducer System. In the context of industrial vibration monitoring, this cable serves as the critical signal transmission link between the proximity probe installed at the machine bearing housing and the Proximitor sensor located in the remote instrumentation cabinet. By maintaining strictly controlled impedance characteristics, this assembly ensures that the high-frequency eddy-current signal remains undistorted during its transit through the plant environment. The \"-CN\" suffix denotes specialized regional compliance, ensuring the assembly meets stringent regulatory standards while providing the physical durability required for harsh, high-vibration industrial sectors. This cable is not merely a wiring accessory; it is a calibrated component of the transducer loop that directly influences the precision of rotor displacement and vibration measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-045-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.5 x 25.4 x 10.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, Shielded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial (Click-loc)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJacket Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluoropolymer (High-Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRegulatory Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (China Standard Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 330130-045-02-CN part number provides a precise technical description of the assembly:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e045: Cable length (4.5 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector configuration (Standard miniature coaxial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Regional configuration (Standardized for specific regulatory compliance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eExtension cables of this caliber are essential for maintaining monitoring system accuracy in complex industrial layouts:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and Steam Turbines: Providing reliable signal pathways from sensors inside hot, high-pressure casings to external control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal Compressors: Facilitating signal transmission across large machinery frames where distance between sensors and monitoring racks is significant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Electric Motors: Ensuring vibration data integrity in environments with high electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydroelectric Generators: Enabling sensor connectivity across large structural footprints in power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePredictive Maintenance Systems: Serving as the backbone for vibration data acquisition in plant-wide condition monitoring programs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330130-045-02-CN is strictly intended for the Bently Nevada 3300 XL transducer ecosystem. It is electrically matched to work in tandem with 3300 XL 8 mm proximity probes and their respective Proximitor sensors. Using this extension cable with legacy 3300 series hardware or non-Bently Nevada systems is strictly advised against, as it will introduce impedance mismatches, signal attenuation, and potential phase shifts that compromise the validity of the rotor dynamics data. When replacing cables in a 3500 Monitoring System, ensure the channel configuration supports the specific length and calibration parameters of this 4.5-meter assembly.\u003c\/p\u003e\n\u003ch3\u003eInstallation Best Practices\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCleanliness: Before coupling, use a non-residue cleaner to ensure the connector mating surfaces are free of oils, dust, or industrial contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Procedure: Firmly engage the click-loc connectors. Ensure a secure, hand-tightened fit; avoid using pliers which can crush the delicate coaxial structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Management: Always route the extension cable through dedicated, grounded metallic conduits. This provides physical protection and serves as a vital shield against high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to a minimum bend radius of at least 5 times the cable diameter to prevent internal dielectric deformation, which can alter electrical impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Strategy: Maintain a single-point ground connection at the instrumentation cabinet to avoid ground loops, which are a common source of 50\/60 Hz signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eImpedance Precision: Engineered to maintain a constant 75-ohm impedance, ensuring the transducer signal remains linear and accurate from the probe to the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Toughness: The high-temperature fluoropolymer jacket is resistant to chemical attack, hydraulic oils, and extreme ambient heat common in turbomachinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterference Rejection: Superior shielding capabilities minimize the risk of external signal degradation, providing clean raw waveform data for sophisticated diagnostic software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless Integration: Designed to be fully compatible with the Bently Nevada 3500 platform, simplifying site-wide maintenance and spare parts standardization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130-045-02-CN Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector dust covers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation instruction document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Always verify the required total cable length against the site layout before ordering, as cable length is a fixed variable in transducer loop calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be used with 5 mm NSv probes?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, 330130 cables are designed for the 8 mm XL system. Using them with 5 mm NSv components will cause severe measurement errors due to impedance mismatch.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 4.5-meter length adjustable in the field?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the cable is a precision-calibrated component. Cutting or splicing the cable will fundamentally change its electrical properties, rendering it unusable.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I know if the extension cable is causing signal noise?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: If you observe high noise floors on the raw waveform or intermittent DC bias shifts, inspect the cable for kinks or loose connectors at the Proximitor end.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable need to be replaced if the probe is changed?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Not necessarily, provided the probe is of the same 3300 XL 8 mm type and the connector condition remains optimal.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I run this cable with power lines?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: It is strongly recommended to route the signal cable in a separate, dedicated conduit away from high-voltage AC lines to prevent induced interference.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are these connectors waterproof?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: They are not designed for direct immersion. They should be housed in a junction box or a protected environment to avoid moisture-related signal attenuation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the significance of the \"CN\" suffix?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The \"CN\" suffix indicates that the assembly complies with specific regional regulatory and manufacturing standards for the target market.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How many times can these connectors be coupled\/uncoupled?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: While durable, the miniature coaxial connectors are designed for a finite number of mating cycles; avoid excessive handling during routine machine maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why does the cable jacket feel stiff?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The fluoropolymer jacket is designed for high-temperature resistance, which naturally makes the cable slightly less flexible than common PVC-based control cables.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should I use tape to seal the cable connections?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Only if recommended by your specific plant safety standards. In most cases, well-seated connectors and a clean, dry junction box are sufficient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518827225261,"sku":"330130-045-02-CN","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-045-02-cn-3300-xl-standard-extension-cable-en3fcyx4ixm.jpg?v=1766979744","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330130-045-02-cn-bently-nevada-extension-cables-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}