{"product_id":"330130-045-00-05-bently-nevada-extension-cable-3300-xl-series","title":"330130-045-00-05 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-045-00-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute non-contacting proximity displacement signal transmission across 3300 XL Series machinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003eCable Option Configurations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: 3300 XL Standard Extension Cable base model designation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e045\u003c\/strong\u003e: 4.5 meters (14.8 feet) total physical cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Standard coaxial cable layout without connector protector options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Multiple global hazardous area agency approvals including CSA, ATEX, and IECEx certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-045-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCenter Conductor Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.222 Ohm\/m nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShield Layer Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.066 Ohm\/m nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe triaxial transmission path maintains precision within the transducer RF loop, transferring high-frequency analog signals between the probe tip and the proximity sensor block. Balanced electrical capacitance and resistance figures preserve exact eddy-current probe scaling over long distances, suppressing voltage distortions under heavy rotor dynamics shifts. Integrated shield layers manage environmental electromagnetic field noise to sustain continuous gap voltage validation parameters.\u003c\/p\u003e\n\u003ch3\u003eDelivery Content Log\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330130-045-00-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Cable Management Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Interface Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJoin the gold-plated click type miniature coaxial connectors together by hand until tight. Do not use structural hand tools to secure the locking mechanism to prevent internal link distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Geometry Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the 4.5 m length through protective steel conduit paths. Ensure any routing orientation curves adhere strictly to the minimum 25.4 mm bend radius restriction to preserve shielding behavior.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation and Terminal Guarding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply high-dielectric insulation sleeves over uninsulated coaxial connector shells. Separate the transducer cable layout paths from high-voltage active motor supply lines to reduce noise cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Infrastructure Verification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this proximity sensor extension cable hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the cable component can be uncoupled or replaced while the corresponding monitor rack channel loop remains energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of violating the minimum bend radius specification?\u003c\/p\u003e\n\u003cp\u003eBending sharper than 25.4 mm permanently alters the core-to-shield capacitance, shifting the loop impedance and degrading calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 4.5 meter cable be paired with any probe length option?\u003c\/p\u003e\n\u003cp\u003eNo, the extension cable length and the proximity probe length when combined must match the exact total electrical system length calibrated for the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific part code include factory-installed connector protectors?\u003c\/p\u003e\n\u003cp\u003eNo, the 00 configuration defines a standard cable variant lacking external composite mechanical connector protectors at the junction points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does moisture contamination affect the coaxial connector connection?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress inside the uninsulated click type connection layer leaks current to ground, resulting in a systemic Not OK monitor status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of signal shielding protection is provided by this architecture?\u003c\/p\u003e\n\u003cp\u003eThe hardware utilizes a specialized FEP jacketed design containing an internal shield layer to eliminate stray industrial field cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat target material is this extension cable system matched to?\u003c\/p\u003e\n\u003cp\u003eThe entire transducer array is factory tuned to track standard AISI 4140 steel target surfaces within the linear range window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the coaxial connector assembly require regular torque verification?\u003c\/p\u003e\n\u003cp\u003eNo, the ClickLoc connection mechanism features a click style lock design meant for secure finger-tight execution without instrumentation tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518809366701,"sku":"330130-045-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-045-00-05-i-o-interface-mrlknv5tbdm.jpg?v=1766979423","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330130-045-00-05-bently-nevada-extension-cable-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}