{"product_id":"330104-09-18-05-01-05-bently-nevada-proximity-probe-3300-xl","title":"330104-09-18-05-01-05 Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-09-18-05-01-05\u003c\/strong\u003e serves as the primary \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe utilized to execute static position mapping and dynamic radial vibration measurements across industrial fluid-film bearing machine platforms.\u003c\/p\u003e\n\u003ch3\u003eNomenclature and Order Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Series\u003c\/strong\u003e: 330104 (8 mm Proximity Probe, standard configuration)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Clearance\u003c\/strong\u003e: 09 (90 mm continuous unthreaded section)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Housing Dimension\u003c\/strong\u003e: 18 (180 mm overall case length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhip Cable Measurement\u003c\/strong\u003e: 05 (0.5 m \/ 1.6 ft integral length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Standard\u003c\/strong\u003e: 01 (Miniature coaxial ClickLoc connector with outer sheath)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e: 05 (Certified compliant with CSA, ATEX, and IECEx directives)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-09-18-05-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.8 x 1.6 x 121 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material Tolerance\u003c\/td\u003e\n\u003ctd\u003eAPI 670 standard carbon steel 4140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Thread Profile\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Output and Rotor Dynamics Profiling\u003c\/h3\u003e\n\u003cp\u003eDesigned for permanent mounting in harsh turbine architectures, the transducer provides stringent eddy-current probe scaling to guarantee linear conversion of shaft proximity into a measurable voltage variable. Initial field calibration mandates strict gap voltage validation (-10.0 VDC baseline targets) when interconnected with the corresponding 3300 XL Proximitor oscillator-demodulator. Coaxial RF shielding coupled with an industrial sheath guarantees cross-talk suppression and isolates the 1 MHz carrier wave from adjacent electromagnetic interference sources.\u003c\/p\u003e\n\u003ch3\u003eStandard Supply Bill of Materials\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330104-09-18-05-01-05 Probe Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Connector Protective Cap Cover\u003c\/li\u003e\n\u003cli\u003e1 x M10 x 1 Hexagonal Locknut\u003c\/li\u003e\n\u003cli\u003e1 x Factory Certification Document Insert\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting Constraints\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gapping Limits\u003c\/strong\u003e: Rotate the probe barrel manually until a multimeter bridged across the Proximitor outputs registers precisely -10.0 VDC, representing approximately 1.27 mm of physical gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking Torque\u003c\/strong\u003e: Apply adequate rotational force to the locking nut to stabilize the case against heavy machine oscillation, avoiding excessive torque that could warp the inner coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Segregation\u003c\/strong\u003e: Maintain strict spatial isolation between the RF signal path and high-current AC motor leads to suppress inductive noise coupling in the analog loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering and Operational FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat defines the unthreaded length of this specific transducer housing?\u003c\/p\u003e\n\u003cp\u003eThe outer casing maintains a 90 mm smooth, unthreaded profile directly behind the tip, indicated by the 09 model suffix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the physical resting distance calibrated during initial commissioning?\u003c\/p\u003e\n\u003cp\u003eField personnel must adjust the threaded engagement toward the conductive target until the Proximitor loop output rests exactly at -10.0 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this physical hardware permit installation in explosive gas atmospheres?\u003c\/p\u003e\n\u003cp\u003eYes, the 05 designation verifies that the component carries factory approvals for CSA, ATEX, and IECEx classified hazardous zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat interface is utilized to bridge the probe to the extension circuit?\u003c\/p\u003e\n\u003cp\u003eThe integrated pigtail ends in a miniature coaxial ClickLoc connector, designed specifically for low-loss radio frequency transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the defined physical span of the built-in sensor wiring?\u003c\/p\u003e\n\u003cp\u003eThe integrated factory-sealed cable measures 0.5 m (1.6 ft) and features an external protective sheath to resist chemical degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this device output standard 4-20 mA process signals directly?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive eddy-current coil that relies on a separate 3300 XL Proximitor device to generate and demodulate the RF field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it permitted to bundle the coaxial extension lines with 220 VAC power cables?\u003c\/p\u003e\n\u003cp\u003eStandard instrumentation practices prohibit this; operators must ensure a minimum 12-inch separation from high-voltage AC lines to prevent signal corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat defines the mechanical fastening standard on the outer probe shell?\u003c\/p\u003e\n\u003cp\u003eThe exterior housing is machined with a standard M10 x 1 metric thread pitch to interface seamlessly with industrial mounting brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025296347309,"sku":"330104-09-18-05-01-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_018_c9be8949-2d0e-4bbf-b746-65d784af48fc.jpg?v=1783654419","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330104-09-18-05-01-05-bently-nevada-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}