{"product_id":"330104-00-20-10-01-cn-bently-nevada-proximity-probes-3300-xl","title":"330104-00-20-10-01-CN Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-20-10-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting shaft displacement and vibration measurements across Bently Nevada 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Selection Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 3300 XL 8 mm Proximity Probe, M10 x 1 metric thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-00: 0 mm unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-20: 200 mm overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-10: 1.0 meter (3.3 feet) total cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-01: Miniature coaxial ClickLoc connector with coaxial cable protection boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-CN: Approvals configuration certified for regional Chinese safety regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-20-10-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 x 15.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Element (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Connector Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc miniature coaxial coupling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis proximity sensor operates on the eddy-current principle to track dynamic shaft behavior and rotor dynamics. The mechanical assembly converts distance parameters into high-frequency RF fields generated by the Proximitor. Field calibration relies on accurate gap voltage validation, targeting a nominal -10 VDC center-scale checkpoint for optimal linearity. Precision tip architecture provides stable eddy-current probe scaling metrics (typically 7.87 V\/mm) while suppressing multi-channel cross-talk in dense radial setups.\u003c\/p\u003e\n\u003ch3\u003eLogistics Dispatch Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330104-00-20-10-01-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Mounting Locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Silicone Protection Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure bracket mounting achieves rigid thread engagement to eliminate case vibration harmonics that distort true target readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Position Adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust the mechanical insertion depth until gap voltage validation registers approximately -10 VDC at the monitor rack test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Isolation Proportions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open cylindrical radius of at least 15 mm around the probe tip to prevent target anomalies from surrounding metal walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Coupling Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHand-tighten the ClickLoc miniature coaxial connector; do not use pliers or mechanical tools to avoid crushing internal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe configuration support hot-swap terminal substitution?\u003c\/p\u003e\n\u003cp\u003eYes. The probe can be physically disconnected from the extension cable while the main Proximitor and monitor rack remain energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does structural surface finish affect eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eSurface defects or microstructural variations modify electrical conductivity, altering the calibrated 7.87 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates a failure in gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA validation reading sitting near 0 VDC or exceeding -18 VDC indicates an open circuit, short circuit, or incorrect mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this model operate with any length of extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. The probe must match the specific system configuration loop length to preserve factory calibration tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing two orthogonal probes?\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum axial separation of 40 mm between probe tips when monitoring identical shaft sections to prevent RF interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating limit of the tip material?\u003c\/p\u003e\n\u003cp\u003eThe PPS fluoropolymer tip holds structural and electrical integrity during continuous thermal exposure up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external isolation barrier required for hazardous area installations?\u003c\/p\u003e\n\u003cp\u003eYes. Intrinsic safety barriers must be wired between the Proximitor sensor loop and the monitoring system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial connector boot is omitted in humid conditions?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases electrical leakage resistance, causing calibration drift and intermittent channel fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807564461,"sku":"330104-00-20-10-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-20-10-01-cn-3300-xl-8-mm-proximity-probes-cdca0eu13zr.jpg?v=1766979357","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330104-00-20-10-01-cn-bently-nevada-proximity-probes-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}