{"product_id":"330104-00-08-90-02-00-bently-nevada-extension-cable-3300-nsv","title":"330104-00-08-90-02-00 Bently Nevada Extension Cable 3300 NSv","description":"\u003cp\u003eConfigured for signal transmission in machinery monitoring frameworks, the \u003cstrong\u003eBently Nevada 330104-00-08-90-02-00\u003c\/strong\u003e (\u003cstrong\u003e330104-00-08-90-02-00\u003c\/strong\u003e Extension Cable) provides direct physical and electrical execution by bridging proximity probes and sensor units.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330104: 3300 NSv extension cable component model family\u003c\/li\u003e\n\u003cli\u003e00: Unthreaded probe style configuration indicator\u003c\/li\u003e\n\u003cli\u003e08: Cable length option code for system interconnection\u003c\/li\u003e\n\u003cli\u003e90: Specialized connector configuration option\u003c\/li\u003e\n\u003cli\u003e02: Agency approval and testing compliance designator\u003c\/li\u003e\n\u003cli\u003e00: Standard manufacturing revision option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-08-90-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 15.0 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive analog transmission path (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Impedance\u003c\/td\u003e\n\u003ctd\u003eMatched coaxial RF transmission line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eMinimum 100 Megaohm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Signal Transmission\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe extension cable preserves eddy-current probe scaling accuracy across extended physical distances between the probe tip and sensor.\u003c\/li\u003e\n\u003cli\u003eProper installation maintains signal integrity to allow precise gap voltage validation targeting -10 VDC baselines.\u003c\/li\u003e\n\u003cli\u003eCross-talk suppression properties minimize electromagnetic coupling when multiple sensor paths route through shared conduits.\u003c\/li\u003e\n\u003cli\u003eHigh-frequency response characteristics support transient rotor dynamics analysis without phase distortion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330104-00-08-90-02-00 Extension Cable\u003c\/li\u003e\n\u003cli\u003e2 x Protective Connector Caps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the coaxial cable inside dedicated metallic conduits to prevent physical damage and environmental contamination.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum bend radii specified for coaxial lines to avoid impedance discontinuities along the signal path.\u003c\/li\u003e\n\u003cli\u003eSecure connectors mechanically using standard finger-tightening followed by a calibrated wrench turn to prevent loosening.\u003c\/li\u003e\n\u003cli\u003eIsolate the shield grounding configuration to a single reference point to eliminate ground loops in the monitoring cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of this extension cable model?\u003c\/p\u003e\n\u003cp\u003eIt connects the proximity probe to the Proximitor sensor while maintaining high-frequency radio frequency signal characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable introduce attenuation into the measurement loop?\u003c\/p\u003e\n\u003cp\u003eThe cable design matches system impedance to prevent signal loss across its specified length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operational temperature limit for the cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe cable withstands continuous environmental temperatures ranging from -51 deg C to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable length be altered in the field?\u003c\/p\u003e\n\u003cp\u003eField cutting or splicing alters electrical resonance and invalidates system calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the connector ends protected during installation?\u003c\/p\u003e\n\u003cp\u003eConnectors feature specialized ClickLoc mechanisms that prevent accidental uncoupling from vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this component require an internal power source?\u003c\/p\u003e\n\u003cp\u003eNo, it is a passive hardware component relying on the Proximitor sensor for excitation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding prevents external electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eAn outer metallic braid and protective fluorocarbon jacket shield the inner coaxial conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with standard 8 mm proximity systems?\u003c\/p\u003e\n\u003cp\u003eIt is engineered specifically to interface within designated 3300 NSv transducer measurement chains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025341468845,"sku":"330104-00-08-90-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian8_fb3b9e9d-8b52-4cf7-8ee8-ce74b95b4e71.jpg?v=1783654340","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330104-00-08-90-02-00-bently-nevada-extension-cable-3300-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}