{"product_id":"330104-00-05-50-02-00-bently-nevada-proximity-probe-3300-xl","title":"330104-00-05-50-02-00 Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eConfigured for non-contact vibration measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-05-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104-00-05-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical electrical execution for radial vibration and axial position sensing across TSI monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded Length (0 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Total Case Length (50 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50: Agency Approval (Multiple Approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Option (Miniature Coaxial ClickLoc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No Standard Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-05-50-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 330104 probe facilitates precise monitoring of rotor dynamics by outputting an eddy-current signal proportional to the gap between the probe tip and the target. To maintain system accuracy, the probe is factory-calibrated to a sensitivity of 7.87 V per mm (200 mV\/mil). Installation requires rigorous gap voltage validation to ensure the steady-state gap voltage is -10 VDC at the linear range midpoint. To prevent erroneous readings in dense sensor arrays, the probe includes internal shielding for cross-talk suppression, ensuring that high-frequency signals are not corrupted by adjacent inductive field interference.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-05-50-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Brass Mounting Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation\/Calibration Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Stability: Ensure the probe bracket is rigid. Any resonant vibration in the bracket will be superimposed on the vibration measurement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductor Routing: Maintain the coaxial cable in conduit to shield against electromagnetic interference. Use a minimum bend radius of 25 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: The probe casing provides a chassis ground through the mounting bracket. Verify that the machine case and instrument signal ground share a common reference point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement: Tactilely confirm that the ClickLoc connector is fully seated to ensure a sealed, low-impedance connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be installed in a standard threaded mounting hole?\u003c\/p\u003e\n\u003cp\u003eNo. The 00 unthreaded option requires a smooth-bore clamp or specifically designed mounting adapter to secure the probe body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe tip protected from chemical damage?\u003c\/p\u003e\n\u003cp\u003eThe PPS tip is chemically inert and designed for immersion in standard turbine lubricating oils and synthetic fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe probe itself is a passive component. Hot-swapping the probe requires disconnecting the extension cable, which will cause a momentary signal loss in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial cable is damaged?\u003c\/p\u003e\n\u003cp\u003eDamage to the shield or core will alter the system impedance, leading to incorrect voltage outputs and potential system-wide vibration measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the -10 VDC gap voltage target universal?\u003c\/p\u003e\n\u003cp\u003eIt is the standard for 3300 XL systems. Deviations from this voltage during setup indicate incorrect gap settings or impedance mismatch in the transducer loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this with a 3300 (non-XL) monitor?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL probe is calibrated for use with XL Proximitors. Using it with non-XL hardware will result in non-linear output and incorrect scale factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the effect of high-temperature operation?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated up to 177 deg C. Exceeding this thermal limit can lead to internal epoxy degradation and permanent sensor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require a specific cable length?\u003c\/p\u003e\n\u003cp\u003eThe probe is part of a calibrated system (Probe + Extension Cable + Proximitor). The total system length must be 5 or 9 meters for proper operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518809465005,"sku":"330104-00-05-50-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-05-50-02-00-3300-xl-8-mm-proximity-probes-fvcu2rz1wkq.jpg?v=1766979428","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330104-00-05-50-02-00-bently-nevada-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}