{"product_id":"330104-00-05-10-01-00-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330104-00-05-10-01-00 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-05-10-01-00\u003c\/strong\u003e serves as the primary \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe utilized to execute non-contacting shaft displacement and vibration measurements across 3300 XL platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Option Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm proximity probe mechanical housing template with flexible armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Designates a 0 mm unthreaded sleeve option profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Allocates a 50 mm minimum overall threaded case length configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Establishes a 1.0 meter (3.3 feet) total hardware cable length parameter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Equips a miniature coaxial ClickLoc connector along with a pre-installed connector protector on standard cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Denotes hazardous location agency approvals are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Indexes\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-05-10-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.5 x 22.2 x 3.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C mechanical tip rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor driven via high-frequency RF signal from Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Cladding\u003c\/td\u003e\n\u003ctd\u003eFlexible stainless steel armored conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm sensing tip relies on automated eddy-current probe scaling to transform magnetic field variations into linear voltage changes. The geometric configuration generates consistent radio frequency field interactions, supporting real-time tracking of rotor dynamics while maintaining high cross-talk suppression between adjacent channels when mounted within shared bearing housings.\u003c\/p\u003e\n\u003ch3\u003eLogistics Packaging Bill\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330104-00-05-10-01-00 3300 XL 8 mm Proximity Probe with Armor\u003c\/li\u003e\n\u003cli\u003e1 x Factory Integrated Coaxial Connector Protector Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Insertion \u0026amp; Locking\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAdvance the M10 x 1 threaded probe barrel into the sensor port slowly until reaching the proper clearance target.\u003c\/li\u003e\n\u003cli\u003eKeep a minimum of 5 full thread engagements inside the mounting boss to withstand machine oscillation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Conduit Routing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the 1.0 meter armored cable away from raw high-voltage motor supply conductors.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum physical bending radius of 25.4 mm (1.0 in) along all physical support clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer Hardware FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat standard gap voltage validation target is required during baseline field calibration?\u003c\/p\u003e\n\u003cp\u003eThe proximity loop relies on standard gap voltage validation targeting a nominal -10 VDC output position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the integrated armor layer alter the continuous physical routing bend radius?\u003c\/p\u003e\n\u003cp\u003eThe stainless steel protective cladding enforces a strict minimum physical bending radius limit of 25.4 mm (1.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 1.0 meter probe module handle high-frequency mechanical vibration loops without data lag?\u003c\/p\u003e\n\u003cp\u003eYes, the proximity probe runs an analog eddy-current loop providing direct physical execution with zero processing latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action occurs if moisture enters the miniature coaxial ClickLoc connector terminal junction?\u003c\/p\u003e\n\u003cp\u003eMoisture changes line impedance, degrading eddy-current probe scaling accuracy and generating false error signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external cooling required when operating the sensor tip near high-temperature journal bearings?\u003c\/p\u003e\n\u003cp\u003eNo, the passive transducer elements safely operate up to +177 deg C under normal convection conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this standard version transducer be mixed with specialized 3300 XL NSv series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo, the 8 mm standard series possesses different tuning and cannot match with NSv series specific Proximitor components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specific mechanical purpose of the factory installed connector protector sleeve?\u003c\/p\u003e\n\u003cp\u003eThe connector protector isolates the coaxial link from touching machine grounding points, stopping ground loop noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat consequence develops if the internal coil path is over-torqued during bracket mounting?\u003c\/p\u003e\n\u003cp\u003eExceeding maximum torque limits deforms the internal wire structures, causing permanent loss of transducer calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026639769773,"sku":"330104-00-05-10-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_f671df58-e824-4c4d-b4c7-7c3d52a57f30.jpg?v=1780476811","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330104-00-05-10-01-00-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}