{"product_id":"330103-05-13-10-02-00-bently-nevada-3300-xl-8mm-series-proximity-probe","title":"330103-05-13-10-02-00 Bently Nevada 3300 XL 8mm Series Proximity Probe","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eBently Nevada 330103-05-13-10-02-00\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"63\"\u003e330103\u003c\/b\u003e Proximity Probe, operates as a dedicated hardware component for non-contacting shaft displacement and vibration measurements within 3300 XL Machinery Protection System configurations. This transducer conversion translates physical gap clearance variations into an electrical voltage directly proportional to static or dynamic movement. The sensor maintains physical separation from the observed target while acquiring fluid-film bearing performance indicators such as radial vibration and axial position.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003ePart Number Variable Matrix\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e330103\u003c\/b\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e05\u003c\/b\u003e: Unthreaded length option (0.5 in \/ 13 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e13\u003c\/b\u003e: Overall case length option (1.3 in \/ 33 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e10\u003c\/b\u003e: Total length option (1.0 m \/ 3.3 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e02\u003c\/b\u003e: Connector option (Miniature coaxial ClickLoc connector with connector protector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e00\u003c\/b\u003e: Agency approval option (No approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003e330103-05-13-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e22.0 cm x 22.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003ePassive sensor component (Powered by remote Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp data-path-to-node=\"13\"\u003eThe 8 mm eddy-current probe scaling is physically calibrated for AISI 4140 steel targets to deliver a predictable voltage response. For precise machine health integration, gap voltage validation requires centering the probe to register a -10 VDC targets reference voltage at the Proximitor output terminal. In multiple-sensor arrangements, cross-talk suppression is maintained by ensuring proper physical distance between probe tips and implementing shielding controls. This physical configuration prevents overlapping magnetic fields from degrading structural rotor dynamics measurements across the orthogonal X-Y radial measurement axes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"15\"\u003ePackage Contents\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e1 330103-05-13-10-02-00 Proximity Probe with 1.0 m integrated coaxial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e2 M10 x 1 Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e1 Pre-installed Coaxial Connector Protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e1 Product Field Reference Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eMechanical Alignment and Torque Limits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"19,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,1,0,0\"\u003eThread the probe into the mounting bracket using a minimum of 5 full threads of engagement to secure the position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,1,1,0\"\u003eAdjust the sensor body until the electrical gap voltage matches specification, then torque the locknuts to a maximum value of 5.1 N-m (45 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eConduit Routing and Shielding Rules\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"19,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,1,0,0\"\u003eBend radii along the coaxial cable must never drop below 25.4 mm (1.0 in) to prevent internal core layer fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,1,1,0\"\u003eRoute all probe lead wires within dedicated metal conduits separate from high-current AC cabling to maintain shield continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"21\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"22\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003eWhat specific gap voltage must be set during initial physical setup?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003eThe hardware alignment must position the probe tip to register a baseline -10 VDC output from the Proximitor, matching the midpoint of the 80 mil linear window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003eCan this probe be connected to a receiver without using a Proximitor sensor?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003eNo, this is a passive eddy-current sensor that requires the matched RF drive and demodulation circuits of a 3300 XL Proximitor to produce a readable signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003eDoes this model option contain an external flexible stainless steel armor layer?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003eNo, the 330103-05-13-10-02-00 part number denotes a standard coaxial cable assembly without the optional flexible outer armor sheath.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,3,0\"\u003eIs the system operation affected if the coaxial cable length is manually modified?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,3,0\"\u003eYes, cutting or splicing the cable alters the precise internal tuning capacitance, which directly shifts calibration parameters and corrupts the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,4,0\"\u003eWhat targets material must be monitored to ensure nominal linear scaling?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,4,0\"\u003eThe factory calibration profile is mapped to AISI 4140 steel; using alternative shaft metals changes the magnetic response and requires system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,5,0\"\u003eIs it permissible to connect or disconnect the probe while the system loop is live?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,5,0\"\u003eYes, hot-swap connections at the coaxial interface will not cause physical or electrical component failure, though a temporary channel fault state will log.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,6,0\"\u003eHow should the miniature ClickLoc coaxial connection be protected from ambient moisture?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,6,0\"\u003eApply the included connector protector cap or wrap the connection with self-fusing silicone tape to prevent moisture from introducing leakage resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,7,0\"\u003eWhat determines the length requirement of the external extension cable for this probe?\u003c\/p\u003e\n\u003cp data-path-to-node=\"22,7,0\"\u003eSince this probe contains an integral 1.0 m lead, it must be paired with a matching 4.0 m or 8.0 m extension cable to achieve a total 5.0 m or 9.0 m system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808973485,"sku":"330103-05-13-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-05-13-10-02-00-3300-xl-8-mm-proximity-probes-pa2cdgbdggl.jpg?v=1766979409","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330103-05-13-10-02-00-bently-nevada-3300-xl-8mm-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}