{"product_id":"330103-00-03-50-02-05-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330103-00-03-50-02-05 Bently Nevada 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for non-contact displacement measurement in vibration monitoring architectures, the \u003cstrong\u003eBently Nevada 330103-00-03-50-02-05\u003c\/strong\u003e (\u003cstrong\u003e330103-00-03-50-02-05\u003c\/strong\u003e Proximity Probes) provides direct physical signal execution within machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: 3300 XL 8 mm\u003c\/li\u003e\n\u003cli\u003eThread: 3\/8-24 UNF\u003c\/li\u003e\n\u003cli\u003eUnthreaded Length: 0.0 in\u003c\/li\u003e\n\u003cli\u003eCase Length: 0.3 in\u003c\/li\u003e\n\u003cli\u003eTotal Length: 5.0 meters (16.4 feet)\u003c\/li\u003e\n\u003cli\u003eConnector: Miniature coaxial ClickLoc\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: CSA, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-03-50-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e104 x 1.5 x 1.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Properties\u003c\/h3\u003e\n\u003cp\u003eThe transducer assembly utilizes eddy-current probe scaling to translate target proximity into a linear voltage signal. System accuracy is contingent upon rigorous gap voltage validation to maintain -10 VDC targets under nominal operating conditions. During installation, technicians must account for rotor dynamics to minimize signal distortion, and ensure adequate cross-talk suppression by maintaining spatial isolation from adjacent high-frequency sensing elements within the machine casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e1 x 330103-00-03-50-02-05 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Threaded lock nut\u003c\/li\u003e\n\u003cli\u003e1 x Installation documentation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Install the probe into the mounting bracket via the 3\/8-24 UNF thread; ensure thread engagement is sufficient to provide structural stability without impacting the target.\u003c\/li\u003e\n\u003cli\u003eGap Setting: Adjust the transducer air gap to align with the required voltage offset, verifying the output with a high-impedance voltmeter.\u003c\/li\u003e\n\u003cli\u003eGrounding: Ensure electrical continuity between the probe housing and the machine chassis as required by the monitoring system's grounding scheme.\u003c\/li\u003e\n\u003cli\u003eCabling: Secure the 5.0 meter coaxial cable using appropriate clamps to prevent mechanical fatigue and avoid routing alongside high-voltage power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the 0.3 in case length?\u003c\/p\u003e\n\u003cp\u003eThe case length defines the physical envelope of the probe body; this short length is suitable for installations where mounting space is restricted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 5.0 meter cable length affect calibration?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for a specific total length; the 5.0 meter length is the standard system length for which the Proximitor sensor impedance is matched.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre these probes compliant with hazardous area requirements?\u003c\/p\u003e\n\u003cp\u003eYes, the model includes CSA, ATEX, and IECEx approvals, permitting operation in designated explosive atmospheres when installed per control drawings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of excessive gap voltage?\u003c\/p\u003e\n\u003cp\u003eVoltage readings significantly offset from the -10 VDC target may indicate a misaligned probe or an approaching limit of the linear operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe monitor axial position?\u003c\/p\u003e\n\u003cp\u003eYes, the probe provides linear displacement data suitable for both radial vibration and axial thrust position measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the ClickLoc connector be handled?\u003c\/p\u003e\n\u003cp\u003eThe connector should be kept free of dirt and oil; use the supplied protector during installation to prevent contamination of the mating surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs backward compatibility supported?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL probe is compatible with legacy 3300 series transducer systems, though complete XL performance features require the full XL system configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat measures prevent signal cross-talk?\u003c\/p\u003e\n\u003cp\u003eMaintain minimum spacing between adjacent probe tips as specified in the installation manual to prevent electromagnetic signal beating between sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026801086637,"sku":"330103-00-03-50-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_af36532e-0cc9-453c-9f61-04d5c4cfab13.jpg?v=1782897926","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330103-00-03-50-02-05-bently-nevada-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}