{"product_id":"330102-00-40-10-02-05-bently-nevada-proximity-transducer-3300-xl-8-mm-proximity-probe","title":"330102-00-40-10-02-05 Bently Nevada Proximity Transducer 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting vibration and position measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330102-00-40-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330102\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical signal generation via eddy-current sensing. This system converts the target displacement into an electrical output signal for downstream monitoring equipment.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330102\u003c\/strong\u003e: 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length (0 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e40\u003c\/strong\u003e: Overall Case Length (40 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length (1.0 meter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector Type (Miniature coaxial ClickLoc connector with connector protector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency Approval (Multiple approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330102-00-40-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 15 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 12 mA (at -24 VDC input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.05 mm (within linear range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes eddy-current probe scaling to convert target proximity into a linear voltage signal. For optimal performance, the gap voltage must be validated at -10 VDC during cold startup to ensure the probe resides in the center of the linear operating range. Rotor dynamics monitoring relies on the signal integrity provided by the probe; improper cable routing or localized electromagnetic interference can introduce signal noise. Suppression of cross-talk is achieved through specific frequency modulation techniques integrated into the Proximitor sensor, ensuring the transducer correctly interprets radial vibration, axial thrust, or differential expansion without harmonic distortion from adjacent probes.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330102 8 mm Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Threaded protective cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Clearance\u003c\/strong\u003e: Ensure the probe tip is installed at the verified nominal gap of 1.27 mm from the target material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Integrity\u003c\/strong\u003e: Utilize high-frequency coaxial cable; avoid sharp bends (minimum bend radius 25 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Ensure the cable shield is grounded only at the monitoring instrument end to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten probe locknuts to a maximum of 5.6 N-m to prevent housing deformation or thread stripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum linear range of this probe?\u003c\/p\u003e\n\u003cp\u003eThe 8 mm probe maintains a linear range of 2.0 mm, typically calibrated between 0.25 mm and 2.29 mm from the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe interchangeable with older 3000 series systems?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL system requires specific Proximitor sensors designed for the 3300 XL 8 mm probe electrical characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does cable length affect calibration?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for a specific total loop length (probe + extension cable). Changing length requires recalibration for accurate output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eIt provides a secure, vibration-resistant connection that prevents accidental disconnection during mechanical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be used in hazardous environments?\u003c\/p\u003e\n\u003cp\u003eYes, provided the installation complies with the specific agency approval codes (e.g., ATEX\/IECEx) indicated in the suffix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the target material important?\u003c\/p\u003e\n\u003cp\u003eThe transducer is calibrated for AISI 4140 steel. Using different target materials will significantly alter the sensitivity and linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes \"Gap Voltage\" drift?\u003c\/p\u003e\n\u003cp\u003eThermal expansion of the machine casing or mechanical settling of the probe bracket are the primary causes of gap voltage changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShould I use thread-locking compounds?\u003c\/p\u003e\n\u003cp\u003eAvoid thread-locking compounds that may interfere with electrical grounding or create chemical compatibility issues with the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025223241901,"sku":"330102-00-40-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_45_7b36069f-24ca-4101-af53-b98be8a21ae3.jpg?v=1783582757","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330102-00-40-10-02-05-bently-nevada-proximity-transducer-3300-xl-8-mm-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}