{"product_id":"330101-24-35-10-02-00-bently-nevada-proximity-probe-3300-xl-series","title":"330101-24-35-10-02-00 Bently Nevada Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-24-35-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal generation based on shaft surface proximity to the transducer tip.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24\u003c\/strong\u003e: Unthreaded Length Option (24 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e35\u003c\/strong\u003e: Total Case Length Option (35 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting Thread\/Connection Style (Standard mount).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-24-35-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 18 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes precise eddy-current probe scaling to ensure linear voltage output corresponding to target displacement. Successful deployment requires gap voltage validation, where the operational gap is typically adjusted to reach a -10 VDC setpoint to maintain linearity within the 2 mm transducer range. Rotor dynamics monitoring depends on the phase-coherent signal transmission through the coaxial cable to the Proximitor sensor. Furthermore, cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple probes are installed in confined machine housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-24-35-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Threaded locknut with safety wire holes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting: Thread the probe into the mounting bracket; ensure at least 5 threads of engagement if using NPT adapters or standard 3\/8-24 jam nut security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Adjust the probe to a gap resulting in -10 VDC output at the nominal shaft position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Path: Ensure the coaxial extension cable is routed away from high-voltage lines or power cables to prevent induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Integrity: Always install the provided connector protector to prevent oil or debris ingress, which can alter electrical impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor of this probe?\u003c\/p\u003e\n\u003cp\u003eThe nominal scale factor for the 3300 XL 8 mm system is 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous environments?\u003c\/p\u003e\n\u003cp\u003eYes, the 02 suffix indicates it is rated for use in hazardous areas, provided it is connected to a certified intrinsic safety barrier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the 24 mm unthreaded length signify?\u003c\/p\u003e\n\u003cp\u003eIt represents the length of the probe case that does not feature external threads, typically used for specific mounting depth requirements in machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe compatible with 3500 series monitors?\u003c\/p\u003e\n\u003cp\u003eThis probe is compatible with the 3300 XL Proximitor; the output from the Proximitor is then processed by the 3500 series vibration monitoring cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify signal integrity?\u003c\/p\u003e\n\u003cp\u003ePerform a static gap test by measuring the voltage between the center conductor and the shield at the Proximitor terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be trimmed to fit a specific distance?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for a 1.0 meter total length; cutting the cable will alter the system impedance and signal linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material should the target be?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for AISI 4140 steel; other materials may require a recalibration factor to ensure measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify if the probe is functioning?\u003c\/p\u003e\n\u003cp\u003eA healthy probe will exhibit a specific capacitance and resistance; use a multimeter to ensure no short or open circuits exist between the center conductor and the case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760640685,"sku":"330101-24-35-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-24-35-10-02-00-proximity-transducer-c3bwfhkatai.jpg?v=1766977013","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330101-24-35-10-02-00-bently-nevada-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}