{"product_id":"330101-00-63-10-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-63-10-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-63-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal generation based on shaft surface proximity to the transducer tip.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length Option (00 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e63\u003c\/strong\u003e: Total Case Length Option (6.3 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting Thread\/Connection Style (Standard mount).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-63-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 20 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to target displacement. Proper installation requires gap voltage validation, where the target operational gap typically centers on a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable and Proximitor sensor. Cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple probes are installed in close proximity on the same machine casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-63-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Threaded locknut with safety wire holes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Stability: Secure the probe using the provided locknut. Ensure the bracket is sufficiently rigid to prevent mechanical resonance at machine operating frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Adjustment: Measure the gap voltage during installation. Adjust the probe position until a reading of -10 VDC is achieved at the nominal shaft position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Keep coaxial cables away from high-current AC lines or variable frequency drive cables to minimize induced electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImpedance Matching: Ensure the total length of the probe and extension cable matches the calibrated length for the specific Proximitor sensor being utilized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor of this probe?\u003c\/p\u003e\n\u003cp\u003eThe nominal scale factor for the 3300 XL 8 mm system is 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThe 02 suffix denotes compliance with standard hazardous area certifications, including ATEX and IECEx, provided appropriate safety barriers are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the connector protector important?\u003c\/p\u003e\n\u003cp\u003eIt provides environmental sealing for the coaxial connector, preventing moisture and contaminants from impacting signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I perform a field check?\u003c\/p\u003e\n\u003cp\u003eUse a digital voltmeter to verify the gap voltage at the monitor or Proximitor output; ensure it remains within the linear range of -1 VDC to -18 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require an armored cable?\u003c\/p\u003e\n\u003cp\u003eThis specific model (00 suffix) does not feature internal armor; it should be installed in protective conduit if subjected to physical impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe detect non-conductive materials?\u003c\/p\u003e\n\u003cp\u003eNo, the eddy-current principle relies on the conductivity and magnetic permeability of the target, typically AISI 4140 steel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage is outside the linear range?\u003c\/p\u003e\n\u003cp\u003eThe output signal becomes non-linear or saturates, leading to inaccurate vibration readings and potential alarm faults in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a faulty probe?\u003c\/p\u003e\n\u003cp\u003eDisconnect the probe and measure continuity; if the center conductor is open or shorted to the shield, the internal coil or cable is damaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760607917,"sku":"330101-00-63-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-63-10-02-00-proximity-probes-iackvt0oi04.jpg?v=1766977012","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330101-00-63-10-02-00-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}