{"product_id":"330101-00-36-10-02-00-bently-nevada-3300-xl-series-proximity-probes","title":"330101-00-36-10-02-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eConfigured for high-speed radial displacement detection within industrial rotating hardware, the \u003cstrong\u003eBently Nevada 330101-00-36-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330101-00-36-10-02-00\u003c\/strong\u003e) Proximity Probes provides direct physical and electrical execution by changing dynamic shaft clearances into continuous low-level voltage variations via electromagnetic induction.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Configuration Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Level\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in minimum unthreaded length specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e3.6 in overall case length specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) cable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-36-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.6 cm x 1.4 cm x 119 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer powered via Proximitor driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Transducer Scaling\u003c\/h3\u003e\n\u003cp\u003eThe measurement architecture implements eddy-current probe scaling to track microscopic clearance changes between the tip and metallic shaft journals. Initial setup requires precise gap voltage validation against standard -10 VDC targets to confirm proper static positioning before machine startup. Continuous analog tracking maps real-time rotor dynamics without mechanical contact or friction drag. Integrated cross-talk suppression minimizes signal bleeding when multiple transducer channels operate in close proximity inside confined compressor housings.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3300 XL 8 mm Proximity Probe (Part Number: 330101-00-36-10-02-00)\u003c\/li\u003e\n\u003cli\u003e1 x 3\/8-24 UNF Mounting Locknut and Washer Set\u003c\/li\u003e\n\u003cli\u003e1 x Product Technical Reference Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Electrical Grounding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eScrew the probe body into the machinery mounting bore, guaranteeing at least 5 full threads are engaged for structural stability.\u003c\/li\u003e\n\u003cli\u003eApply calibrated torque to the mounting hardware while ensuring no rotational twisting forces are transferred to the coaxial line.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring physically separated from high-current motor leads to eliminate electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect the outer shield drain wire exclusively to the instrument rack earth ground to prevent ground loop interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the factory-calibrated sensitivity or scale factor for this probe variant?\u003c\/li\u003e\n\u003cli\u003eA: The sensor delivers a linear output of 7.87 V\/mm (200 mV\/mil) across its primary operating span.\u003c\/li\u003e\n\u003cli\u003eQ: How do wide temperature shifts influence the output signal accuracy?\u003c\/li\u003e\n\u003cli\u003eA: Internal electrical compensation networks stabilize the output across the rated -51 deg C to 177 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eQ: Why is the -10 VDC gap voltage checked during initial mechanical alignment?\u003c\/li\u003e\n\u003cli\u003eA: It places the operational bias exactly at the midpoint of the linear output characteristic curve.\u003c\/li\u003e\n\u003cli\u003eQ: Is this hardware rated for installation in volatile or explosive zones?\u003c\/li\u003e\n\u003cli\u003eA: No, this specific variant utilizes the standard approval-free configuration option.\u003c\/li\u003e\n\u003cli\u003eQ: What mechanical margin is necessary for safe probe mounting?\u003c\/li\u003e\n\u003cli\u003eA: Installers must maintain a minimum of 5 full thread engagements to withstand intense operational vibration.\u003c\/li\u003e\n\u003cli\u003eQ: Does this device require an internal battery or active DC connection?\u003c\/li\u003e\n\u003cli\u003eA: No, it operates as a passive transducer driven entirely by the remote Proximitor oscillator-demodulator module.\u003c\/li\u003e\n\u003cli\u003eQ: How can coaxial connectors be safeguarded against liquid contamination?\u003c\/li\u003e\n\u003cli\u003eA: Use ClickLoc connectors coupled inside moisture-resistant weatherproof junction enclosures.\u003c\/li\u003e\n\u003cli\u003eQ: Are replacement extension cables interchangeable across different series variants?\u003c\/li\u003e\n\u003cli\u003eA: No, extension cables must strictly match the electrical capacitance specifications of the 3300 XL system design.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025296707757,"sku":"330101-00-36-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_d7b5c2ab-480c-4975-81cb-1390da6b98c6.jpg?v=1783592144","url":"https:\/\/www.maxwellplc.com\/ga\/products\/330101-00-36-10-02-00-bently-nevada-3300-xl-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}