{"product_id":"3300-16-01-01-02-01-00-02-bently-nevada-3300-system-xy-gap-monitor","title":"3300\/16-01-01-02-01-00-02 Bently Nevada 3300 System XY\/GAP Monitor","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/16-01-01-02-01-00-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300\/16\u003c\/strong\u003e XY\/GAP Dual Vibration Monitor, operates as a dedicated hardware component for dual vibration and shaft gap signal monitoring within the Bently Nevada 3300 Monitoring System.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/16-01-01-02-01-00-02 configuration defines an XY\/GAP Dual Vibration Monitor with a 0-3 mils peak-to-peak full-scale range, compatible with Bently Nevada 3300 8 mm, 3300 XL 8 mm, and 7200 5 mm \/ 8 mm Proximitor Sensor systems.\u003c\/p\u003e\n\u003cp\u003eThe model configuration includes a 200 mV\/mil transducer input option, hermetically-sealed alarm relay outputs, CSA\/NRTL\/C agency approval, no safety barrier option, and 3X trip multiply function.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-01-01-02-01-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eXY\/GAP Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-3 mils peak-to-peak (pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 8 mm, 3300 XL 8 mm, 7200 5 mm and 8 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Option\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier Option\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply Option\u003c\/td\u003e\n\u003ctd\u003e3X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5 x 32.2 x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eShaft Vibration Signal Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/16 XY\/GAP Dual Vibration Monitor processes vibration and gap measurement signals received from compatible Bently Nevada Proximitor Sensors. The module accepts displacement-related signals generated by eddy-current probe systems using the specified 200 mV\/mil sensitivity scale.\u003c\/p\u003e\n\u003cp\u003eThe GAP channel provides monitoring of probe gap voltage conditions, allowing verification of probe operating position within the measurement range. Proper gap voltage validation is required for accurate shaft displacement measurement and vibration waveform interpretation.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics Measurement Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/16 supports XY vibration monitoring configurations where two orthogonal vibration channels are evaluated for machinery rotor behavior. The dual-channel arrangement enables analysis of radial vibration characteristics and supports rotor dynamics evaluation.\u003c\/p\u003e\n\u003cp\u003eThe Proximitor Sensor input interface uses eddy-current measurement principles, requiring correct probe scaling and cable installation practices. Shielding, signal routing, and grounding methods influence cross-talk suppression between adjacent vibration channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 3300\/16-01-01-02-01-00-02 XY\/GAP Dual Vibration Monitor\u003c\/li\u003e\n\u003cli\u003e1 x 3300 System compatible monitoring module assembly\u003c\/li\u003e\n\u003cli\u003e1 x Standard hardware configuration according to selected options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eRack Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the monitor module in the designated Bently Nevada 3300 rack position.\u003c\/li\u003e\n\u003cli\u003eVerify rack power availability before inserting the module.\u003c\/li\u003e\n\u003cli\u003eConfirm module configuration matches the connected Proximitor Sensor type.\u003c\/li\u003e\n\u003cli\u003eFollow approved grounding practices for machinery monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSignal Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse appropriate shielded wiring between Proximitor Sensors and monitoring inputs.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between vibration signal cables and high-current electrical conductors.\u003c\/li\u003e\n\u003cli\u003eVerify probe polarity and terminal connections before startup.\u003c\/li\u003e\n\u003cli\u003eConfirm gap voltage conditions before collecting vibration data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function does the 3300\/16 module perform?\u003c\/p\u003e\n\u003cp\u003eThe 3300\/16 provides XY vibration and GAP monitoring using compatible Bently Nevada Proximitor Sensor inputs within the 3300 System.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich sensors are compatible with this configuration?\u003c\/p\u003e\n\u003cp\u003eThe module supports 3300 8 mm, 3300 XL 8 mm, and 7200 5 mm or 8 mm Proximitor Sensors with 200 mV\/mil sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the vibration measurement range?\u003c\/p\u003e\n\u003cp\u003eThis configuration provides a full-scale vibration range of 0-3 mils peak-to-peak (pp).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the GAP measurement channel monitor?\u003c\/p\u003e\n\u003cp\u003eThe GAP channel monitors probe position conditions through the eddy-current sensor gap voltage output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include a safety barrier option?\u003c\/p\u003e\n\u003cp\u003eThe supplied configuration specifies no safety barrier option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat alarm relay type is included?\u003c\/p\u003e\n\u003cp\u003eThe selected alarm relay option is a hermetically-sealed relay configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the 3X trip multiply option provide?\u003c\/p\u003e\n\u003cp\u003eThe 3X trip multiply function changes the monitoring trip level scaling for temporary operating conditions requiring expanded vibration limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should sensor wiring be installed?\u003c\/p\u003e\n\u003cp\u003eSensor cables should be routed away from interference sources with correct shielding and grounding practices applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026435133613,"sku":"3300\/16-01-01-02-01-00-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3300-163_19e4027b-45be-417d-9ed1-0c1c2d7d1026.jpg?v=1785741690","url":"https:\/\/www.maxwellplc.com\/ga\/products\/3300-16-01-01-02-01-00-02-bently-nevada-3300-system-xy-gap-monitor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}