{"product_id":"32000-29-10-04-055-03-02-bently-nevada-housing-new-stock","title":"32000-29-10-04-055-03-02 Bently Nevada Housing | New Stock","description":"\u003cp\u003eConfigured for radial vibration and axial thrust measurements in rotating machinery protection systems, the \u003cstrong\u003eBently Nevada 32000-29-10-04-055-03-02\u003c\/strong\u003e (\u003cstrong\u003e32000\u003c\/strong\u003e Proximity Probe Housing Assembly) provides direct physical protection and environmental sealing for internal transducers.\u003c\/p\u003e\n\u003ch3\u003ePart Number Code Structure\u003c\/h3\u003e\n\u003cp\u003eThe mechanical and accessory configurations of this metric proximity probe housing assembly are designated by the following options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32000\u003c\/strong\u003e: Base model number for the English\/Metric Proximity Probe Housing Assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-29\u003c\/strong\u003e: Integrates a 3300 XL 8 mm proximity probe with a connector protector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Configures a probe cable length of 1.0 m (39 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04\u003c\/strong\u003e: Specifies a standoff adapter length of 40 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-055\u003c\/strong\u003e: Configures a probe penetration depth of 55 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-03\u003c\/strong\u003e: Includes two plugs, one M20 fitting, and one cable seal grip with grommets for armored probe cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Selects a 3\/4-14 NPT mounting thread option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32000-29-10-04-055-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e37.0 x 9.0 x 8.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C (probe tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive housing (probe driven by external -24 VDC Proximitor loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS) and AISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X and IP66 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Sealing\u003c\/td\u003e\n\u003ctd\u003eViton O-ring (probe case), Neoprene O-ring (sleeve-to-housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Entry Option\u003c\/td\u003e\n\u003ctd\u003eMetric M20 fitting and protective plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n\u003ctd\u003eArmored probe cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eThe integrated 3300 XL 8 mm probe within the 32000-29-10-04-055-03-02 housing utilizes high-frequency eddy-current probe scaling to convert physical dynamic distance into proportional voltage. The system tracks rotor dynamics by generating a magnetic field at the probe tip, interacting with the target shaft of turbines, compressors, or pumps.\u003c\/p\u003e\n\u003cp\u003eTo ensure precise monitoring without signal distortion, a physical gap voltage validation must be performed during commissioning. Technicians adjust the axial depth of the probe within the sleeve until the output measures a target of -10 VDC. This sets the probe in the center of its linear range, enabling optimal resolution for shaft vibration and cross-talk suppression.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 32000-29-10-04-055-03-02 Housing Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Integrated 3300 XL 8 mm proximity probe with connector protector\u003c\/li\u003e\n\u003cli\u003e2 x Sealing plugs\u003c\/li\u003e\n\u003cli\u003e1 x M20 conduit fitting\u003c\/li\u003e\n\u003cli\u003e1 x Cable seal grip with grommets for armored cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifying Mount Thread Sealing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply industrial-grade liquid thread sealant to the 3\/4-14 NPT mounting thread. Ensure a minimum of five full threads of engagement into the machine case to guarantee mechanical stability under heavy vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelecting Correct Cable Grommets\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUtilize the specialized grommets included with option 03 to seal the armored probe cable. The grommet must match the outer diameter of the armor jacket to prevent lubricating oil or moisture from entering the housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal O-Ring Ingress Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the Neoprene O-ring located between the sleeve and the housing body before locking down the position. This seal is necessary to maintain NEMA 4X and IP66 ratings against hose-directed water.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the target gap voltage validated for this specific housing assembly?\u003c\/p\u003e\n\u003cp\u003eA digital voltmeter is connected to the associated Proximitor loop while the probe is adjusted mechanically inside the sleeve to achieve a target of -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the internal 3300 XL probe be replaced without stopping the machine?\u003c\/p\u003e\n\u003cp\u003eYes, the housing allows external access, permitting technicians to withdraw the sleeve and replace the probe without machinery disassembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the PPS plastic housing resist high pressure within turbine casings?\u003c\/p\u003e\n\u003cp\u003eNo, the housing seals against fluid splash and low differential pressure but is not designed or rated to contain high internal casing pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the benefit of the integrated connector protector (Option 29)?\u003c\/p\u003e\n\u003cp\u003eThe connector protector physically shields the miniature coaxial connection from environmental contaminants and prevents accidental unmating during thermal cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan standard unarmored extension cables be routed through this housing?\u003c\/p\u003e\n\u003cp\u003eThe option 03 configuration is specifically optimized with grommets for armored cables, though standard cables can be routed if compatible sealing grommets are sourced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the physical function of the 40 mm standoff adapter?\u003c\/p\u003e\n\u003cp\u003eThe standoff adapter positions the main body of the housing 40 mm away from the machine case, allowing proper clearance for the 55 mm probe penetration depth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does incorrect thread engagement affect the measurement signals?\u003c\/p\u003e\n\u003cp\u003eInsufficient engagement allows the housing to flex or vibrate independently of the machine case, introducing mechanical noise and skewing rotor dynamics data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe factory calibrated for non-magnetic target shafts?\u003c\/p\u003e\n\u003cp\u003eThe probe is calibrated for standard AISI 4140 steel targets; alternative target metals will alter the eddy-current scaling curve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025805201581,"sku":"21504-000-032-10-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_98_69ee1053-e2dc-4148-aeb3-a30d44a947a2.jpg?v=1784279815","url":"https:\/\/www.maxwellplc.com\/ga\/products\/32000-29-10-04-055-03-02-bently-nevada-housing-new-stock","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}