{"product_id":"32000-28-05-05-060-00-02-bently-nevada-proximity-probe-housing-assembly-32000-series","title":"32000-28-05-05-060-00-02 Bently Nevada Proximity Probe Housing Assembly 32000 Series","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 32000-28-05-05-060-00-02\u003c\/strong\u003e serves as the primary \u003cstrong\u003e32000\u003c\/strong\u003e Proximity Probe Housing Assembly utilized to execute radial vibration and axial thrust measurements across 3300 XL Series monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Code Definitions\u003c\/h3\u003e\n\u003cp\u003eThe mechanical configurations of this English proximity probe housing assembly are designated by the following options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32000\u003c\/strong\u003e: Base model number for the English Proximity Probe Housing Assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-28\u003c\/strong\u003e: Integrates a 3300 XL 8 mm proximity probe with multiple approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Configures a probe cable length of 0.5 m (20 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Selects a standoff adapter length of 0.5 in (12.7 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-060\u003c\/strong\u003e: Configures a probe penetration depth of 6.0 in (152.4 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Ships without fittings; includes two plugs and two washers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Selects a 3\/4-14 NPT mounting thread option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32000-28-05-05-060-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e37.0 x 9.0 x 8.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C (probe portion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (housing only, probe operates on -17.5 VDC to -26 VDC loop power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X and IP66 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS) and AISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Materials\u003c\/td\u003e\n\u003ctd\u003eViton internal probe O-ring, Neoprene sleeve-to-housing O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitted Accessories\u003c\/td\u003e\n\u003ctd\u003eTwo plugs and two washers (no conduit fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal 3300 XL 8 mm probe operates through high-frequency eddy-current probe scaling, converting physical displacement into proportional electrical voltage. Because the probe is housed within the 32000-28-05-05-060-00-02 protective casing, field calibration requires careful mechanical adjustment.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, gap voltage validation is performed by sliding the probe within the sleeve until a nominal target voltage of -10 VDC is met. This ensures the probe is centered within its linear range, enabling precise tracking of high-frequency rotor dynamics on turbomachinery without signal clipping.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 32000-28-05-05-060-00-02 Housing Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Integrated 3300 XL 8 mm proximity probe with multiple approvals\u003c\/li\u003e\n\u003cli\u003e2 x Sealing plugs\u003c\/li\u003e\n\u003cli\u003e2 x Washers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eO-Ring Inspection and Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the internal Viton O-ring and the Neoprene sleeve-to-housing O-ring are intact. These elastomer barriers prevent oil mist migration and maintain NEMA 4X \/ IP66 ingress ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement and Torquing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure a minimum of five full threads of engagement when mounting the 3\/4-14 NPT body into the machine case. Apply industrial-grade thread sealant to prevent mechanical loosening caused by continuous machinery vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Coupling and Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the coaxial leads using ClickLoc connectors on the 0.5-meter cable, tightening until they audibly \"click\". Coil the coaxial excess neatly inside the housing dome, avoiding tight bends to prevent cable pinching when sealing the cover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the target gap voltage validated when using this housing assembly?\u003c\/p\u003e\n\u003cp\u003eA multimeter is connected to the Proximitor loop while the probe depth is mechanically adjusted within the housing sleeve to achieve the nominal -10 VDC calibration baseline.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre 3300 XL 8 mm probes hot-swappable while the machine is running?\u003c\/p\u003e\n\u003cp\u003eYes, the housing design allows the probe and sleeve to be safely withdrawn and replaced from the exterior of the machine casing without shutting down the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this housing assembly resist internal machine casing pressure?\u003c\/p\u003e\n\u003cp\u003eThe Viton O-rings seal against differential pressure, but the PPS plastic housing is designed to shield against environmental hazards and is not rated for high-pressure containment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 0.5 inch standoff adapter option on this model?\u003c\/p\u003e\n\u003cp\u003eThe standoff adapter extends the physical position of the housing shell away from the machine wall, allowing precise alignment for the 6.0 in penetration option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan a 7200 Series extension cable be paired with the integrated probe?\u003c\/p\u003e\n\u003cp\u003eNo, 3300 XL probes are electrically incompatible with 7200 Series extension cables and Proximitors due to distinct electrical parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat materials are compatible with the default eddy-current calibration of this sensor?\u003c\/p\u003e\n\u003cp\u003eThe scaling of the probe is calibrated for AISI 4140 steel; using other target shaft alloys will skew the linear measurement and require calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the Neoprene sleeve-to-housing O-ring is damaged?\u003c\/p\u003e\n\u003cp\u003eMoisture and particulates will breach the internal chamber, causing degradation of the coaxial cable connection and potential signal drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy does this specific model option (00) include plugs but no conduit fittings?\u003c\/p\u003e\n\u003cp\u003eOption 00 is configured for installations where the customer provides their own liquid-tight conduit couplers or routes armored cable through existing cable seals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025799172269,"sku":"32000-28-05-05-060-00-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_45_a7c77e69-3f41-4b55-87fd-216676353a22.jpg?v=1784278650","url":"https:\/\/www.maxwellplc.com\/ga\/products\/32000-28-05-05-060-00-02-bently-nevada-proximity-probe-housing-assembly-32000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}