{"product_id":"32000-16-05-00-080-03-02-bently-nevada-proximity-probe-housing-32000-series","title":"32000-16-05-00-080-03-02 Bently Nevada Proximity Probe Housing 32000 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 32000-16-05-00-080-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Housing, operates as a dedicated hardware component for the mechanical positioning and environmental protection of eddy-current proximity probes within machine casings.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 32000-16-05-00-080-03-02 part number specifies the housing geometry and interface requirements. The configuration denotes an 80 mm length, 1\/2-20 UNF probe thread interface, and a 1\/2-inch NPT mounting thread. This assembly provides the structural mounting required to align the probe tip accurately relative to the target, ensuring stable operation within mechanical monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32000-16-05-00-080-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 10 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (None)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-inch NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-20 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Transducer Scaling\u003c\/h3\u003e\n\u003cp\u003eAccurate rotor dynamics monitoring depends on the mechanical stability of the housing assembly. The 32000 series allows for precise axial adjustment of the transducer tip to facilitate the -10 VDC gap voltage validation necessary for linear signal response. To maintain integrity, the housing must be rigidly secured to the machine casing using the included jam nut, preventing movement induced by shaft vibration. Cross-talk suppression should be maintained by ensuring adequate physical separation between multiple probe housings installed in close proximity.\u003c\/p\u003e\n\u003ch3\u003e Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1x 32000-16-05-00-080-03-02 Probe Housing Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Lock nut and O-ring seal kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Installation technical guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSurface Preparation: Prepare the mounting boss with a hole tapped perpendicular to the target surface to prevent angular alignment deviations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSealing: Utilize a thread sealant compatible with the operating environment on the NPT mounting threads to prevent casing fluid leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustment: Thread the housing into the mounting boss and adjust until the probe tip is set to the required -10 VDC gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLockdown: Tighten the jam nut to 5.1 N-m (45 in-lb) to secure the housing position against mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this housing compatible with all Bently Nevada probes? The housing is designed for standard probe thread diameters (1\/2-20 UNF); verify compatibility with specific probe models before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace the O-ring in the field? Yes, the O-ring is a consumable component and should be inspected during every maintenance outage for signs of degradation or wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 80 mm length? This length provides the necessary reach to position the probe tip at the correct distance from the shaft in machines with thick casing walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent thread seizing? Use a compatible anti-seize compound on the threads if the housing is required to be removed periodically for inspection or calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this housing include the proximity probe? No, the 32000 series is a mechanical mounting assembly; the transducer probe and extension cable are sourced as separate components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the housing be used in high-vibration applications? Yes, the assembly is robust, but ensure the mounting boss is not subject to structural fatigue that could affect signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the pressure rating of the housing? The seal integrity depends on the NPT installation; ensure the sealant is rated for the internal pressure of the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is perpendicular alignment critical? Any angular deviation from 90 degrees relative to the shaft surface creates non-linearities in the eddy-current probe output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518836531373,"sku":"32000-16-05-00-080-03-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-32000-16-05-00-080-03-02-proximity-probe-housingassemblies-l4jdnh4bu2c.jpg?v=1766980052","url":"https:\/\/www.maxwellplc.com\/ga\/products\/32000-16-05-00-080-03-02-bently-nevada-proximity-probe-housing-32000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}