{"product_id":"20g11nc3p5ja0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20G11NC3P5JA0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20G11NC3P5JA0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20G11NC3P5JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, operates as a dedicated hardware component for motor speed regulation and torque control within industrial power conversion platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 20G11NC3P5JA0NNNNN configuration designates an air-cooled PowerFlex 753 unit engineered for 400 VAC\/540 VDC input operation. The model architecture includes integrated precharge circuitry and internal transistors, housed in an IP20\/IP00 open-type chassis. This specific build excludes a Human Interface Module (HIM) and provides filtering for electromagnetic compatibility.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20G11NC3P5JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kW (2 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Drive Control Attributes\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform utilizes high-speed internal processing to support deterministic EtherNet\/IP and common industrial protocol (CIP) networks. The architecture supports firmware flash compatibility, allowing localized updates to control loops and motion profiles. I\/O density scaling is achieved through modular option cards, enabling precise synchronization of drive axes within multi-drive automation systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20G11NC3P5JA0NNNNN AC Drive Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x User Terminal Block set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical Installation Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Management:\u003c\/p\u003e\n\u003cp\u003eEnsure the drive is mounted in a vertical orientation within a clean, ventilated enclosure to maintain convective cooling airflow across the heatsink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Isolation:\u003c\/p\u003e\n\u003cp\u003eRoute signal and power cabling through separate metallic conduits to prevent crosstalk and noise injection into sensitive control circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Strategy:\u003c\/p\u003e\n\u003cp\u003eConnect the chassis ground terminal directly to the equipment safety ground bus using a low-impedance conductor to ensure reference potential stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance Requirements:\u003c\/p\u003e\n\u003cp\u003eProvide a minimum of 15 cm of vertical clearance above and below the unit to allow for sufficient air volume during continuous operation at rated load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 20G11NC3P5JA0NNNNN be operated without a HIM?\u003c\/p\u003e\n\u003cp\u003eYes. The drive can be commissioned and operated via external control signals or network commands, provided the initial parameters are configured through software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it possible to perform a hot-swap of the drive during operation?\u003c\/p\u003e\n\u003cp\u003eNo. The input power must be completely disconnected and the DC bus must be verified as fully discharged before attempting to remove or install the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the internal precharge circuit?\u003c\/p\u003e\n\u003cp\u003eThe precharge circuit limits the inrush current to the DC bus capacitors during initial power-up, preventing damage to the input rectifier bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal transistors included in this build?\u003c\/p\u003e\n\u003cp\u003eYes. This model is equipped with an internal dynamic braking transistor, which allows for the connection of an external braking resistor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the firmware updated on this unit?\u003c\/p\u003e\n\u003cp\u003eFirmware updates are executed via the drive communication port using the manufacturer's dedicated engineering workstation software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model support DC input?\u003c\/p\u003e\n\u003cp\u003eYes. The drive is rated for 540 VDC input, allowing for operation on a common DC bus configuration as specified in the technical manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the installed jumper?\u003c\/p\u003e\n\u003cp\u003eThe factory-installed jumper typically links the control board and safety circuitry; verify the schematic before removal to avoid disabling critical hardware functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protection rating does the IP00 enclosure offer?\u003c\/p\u003e\n\u003cp\u003eIP00 indicates that the unit provides no protection against solid objects or liquids; it must be installed within an appropriate NEMA\/UL-rated secondary enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066470453421,"sku":"20G11NC3P5JA0NNNNN","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20G11Nc8-1_33e3432e-47d0-4dd0-939b-ba5ef0a4262d.jpg?v=1782294505","url":"https:\/\/www.maxwellplc.com\/ga\/products\/20g11nc3p5ja0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}