{"product_id":"20f1and156jn0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F1AND156JN0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1AND156JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20F1AND156JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive utilized to execute precise motor velocity and torque regulation across EtherNet\/IP platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix \u0026amp; Hardware Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 20F1AND156JN0NNNNN is a PowerFlex 753 hardware build configured for 480 VAC, 3-phase input. The unit features integrated precharge circuitry, EMC filtering, and an internal dynamic braking (DB) transistor for active energy dissipation. The architecture is housed in a Frame 6 open-type IP20\/IP00 chassis, equipped with embedded I\/O blocks for direct sensor and feedback integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1AND156JN0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 HP (Normal Duty) \/ 100 HP (Heavy Duty)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 VAC \/ 650 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e156 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform utilizes high-speed backplane bus communication to maintain deterministic performance across industrial networks. The drive supports firmware flash compatibility, facilitating periodic updates to motor control algorithms and protective logic. Modular option cards enable I\/O density scaling, ensuring seamless integration with existing PLC and DCS architectures while maintaining strict timing tolerances for motion control applications.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20F1AND156JN0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal block connector set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Management:\u003c\/p\u003e\n\u003cp\u003eMount the Frame 6 chassis vertically within a climate-controlled cabinet. Ensure that the forced-air cooling system remains unblocked to prevent thermal shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding \u0026amp; Shielding:\u003c\/p\u003e\n\u003cp\u003eEstablish a low-impedance path to ground using the chassis PE terminal. Shielded cables must be utilized for all signal lines to suppress electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling Segregation:\u003c\/p\u003e\n\u003cp\u003eMaintain physical separation between high-voltage power leads and low-voltage control lines to prevent capacitive coupling and induced signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Constraints:\u003c\/p\u003e\n\u003cp\u003eIP00-rated enclosures require placement within a NEMA\/UL-certified secondary cabinet to prevent the ingress of conductive debris or ambient humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DB transistor handle continuous braking?\u003c\/p\u003e\n\u003cp\u003eNo. The DB transistor is rated for periodic duty cycles. Ensure that the external braking resistor sizing matches the calculated kinetic energy discharge requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the drive compatible with single-phase power?\u003c\/p\u003e\n\u003cp\u003eNo. This unit is strictly designed for 480 VAC 3-phase input. Connecting to a single-phase supply will result in input phase loss faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo. The drive must be isolated from power, and the DC bus must be verified as fully discharged to 0 VDC before any physical maintenance is performed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the CM jumper?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper provides common-mode interference suppression. It must remain installed to meet standard EMC filter performance criteria.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal fuses user-replaceable?\u003c\/p\u003e\n\u003cp\u003eNo. This is a field-replaceable unit (FRU). There are no user-serviceable components or fuses located inside the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the embedded I\/O managed?\u003c\/p\u003e\n\u003cp\u003eEmbedded I\/O parameters are configured via the drive firmware through the communication port using standard engineering software tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage deviates?\u003c\/p\u003e\n\u003cp\u003eThe drive monitor will trigger an overvoltage or undervoltage trip if the input exceeds or falls below the nominal operating range, preventing damage to the inverter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan firmware be updated remotely?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware can be updated via the drive's communication network using the manufacturer's provided flash utility tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066467700909,"sku":"20F1AND156JN0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-3_66ac4a4a-e103-4088-b006-5ae6eff06ae1.jpg?v=1782441821","url":"https:\/\/www.maxwellplc.com\/ga\/products\/20f1and156jn0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}