{"product_id":"20f11nd096ja0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20F11ND096JA0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eConfigured for high-torque motor control applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11ND096JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F11ND096JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical\/electrical execution. This PowerFlex 753 drive operates on a 480 VAC, 3-phase supply and incorporates embedded I\/O modules to facilitate localized control logic. The hardware architecture supports both normal duty and heavy duty output profiles, utilizing an open-type chassis with forced-air cooling to manage thermal output during high-current operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11ND096JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 VAC \/ 650 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (ND)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e96 A (75 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (HD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e77 A (60 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ IP00 Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Network and I\/O Integration\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 series utilizes modular firmware to manage deterministic network communication, providing full compatibility with EtherNet\/IP and other industrial protocols. The system supports complex I\/O density scaling, allowing users to configure local and remote inputs and outputs through the drive’s backplane bus. Firmware flash compatibility is built into the processor architecture, enabling field-side updates to network stacks or drive control algorithms. This ensures that the drive integrates seamlessly into multi-axis systems, maintaining timing precision and deterministic signal exchange across the control platform.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 20F11ND096JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 I\/O terminal block set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Technical documentation packet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the drive in a vertical orientation within an enclosure rated for the local environment to ensure proper heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvide at least 150 mm of clearance above and below the drive to facilitate unobstructed airflow for the forced-air cooling system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate all power and control shielding to a low-impedance ground point to minimize noise influence on the internal signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the CM jumper remains installed to maintain established EMC filtering levels as specified in the technical documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this drive support hot-swapping of control modules?\u003c\/p\u003e\n\u003cp\u003eNo, all control modules and I\/O cards must be installed or removed while the drive is powered down to prevent damage to the backplane communication bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the HD (Heavy Duty) rating determined?\u003c\/p\u003e\n\u003cp\u003eThe HD rating is based on increased current capacity for applications with high starting torque requirements; users must select the correct mode via the drive software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive operate without the CM jumper?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper is required for proper EMC filtering; removing it may increase conducted electrical noise and affect compliance with electromagnetic compatibility standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the drive's internal temperature exceeds the limit?\u003c\/p\u003e\n\u003cp\u003eThe drive will trigger a thermal fault and cease output to the motor, protecting the power stage from damage until the temperature drops within the safe operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 96 A rating continuous?\u003c\/p\u003e\n\u003cp\u003eYes, the 96 A rating is the continuous output current for normal duty (ND) operation; temporary overloads are handled according to the factory-set overload curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the DC terminals?\u003c\/p\u003e\n\u003cp\u003eThe DC terminals allow for connection to a common DC bus, enabling energy sharing between drives in multi-drive configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the drive include an internal brake?\u003c\/p\u003e\n\u003cp\u003eThis model includes a Dynamic Braking (DB) transistor, which allows for the connection of an external braking resistor to dissipate regenerated energy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I configure parameters without a HIM?\u003c\/p\u003e\n\u003cp\u003eParameters can be configured using a PC connected via the drive’s communication port running the appropriate configuration software or via a temporary plug-in HIM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066464555181,"sku":"20F11ND096JA0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-66_3ce63f2d-2aa1-422b-bb4c-2aed8656819b.jpg?v=1782445998","url":"https:\/\/www.maxwellplc.com\/ga\/products\/20f11nd096ja0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}