{"product_id":"20f11nc104ja0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F11NC104JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11NC104JA0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive utilized to execute variable frequency motor speed regulation across EtherNet\/IP deterministic networks platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameter Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11NC104JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 kW ND \/ 45 kW HD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC, 3 PH \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e104 Amps continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Type (IP20\/IP00, NEMA\/UL Type Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Input with DC Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Filtering Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiltered, CM jumper installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Braking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal DB Transistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHuman Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIM Blank (No HIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Backplane and Control Integration\u003c\/h3\u003e\n\u003cp\u003eThis Frame 5 drive platform handles real-time velocity instruction sequencing over EtherNet\/IP deterministic networks. High-density firmware flash compatibility ensures that internal regulation modules stay synchronized with Allen-Bradley Logix processor backplanes without introducing communication phase drift. Local peripheral instrumentation loops connect directly to the embedded I\/O sub-board, resolving feedback signals at the chip level to bypass external field network propagation delays.\u003c\/p\u003e\n\u003ch3\u003eSupply Kit Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F11NC104JA0NNNNN PowerFlex 753 Drive Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Calibration and Hardware QC Pass Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Frame 5 Electrical Integration Reference Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Grounding Criteria\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Axis Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFix the drive chassis strictly in a vertical plane on a flat, unyielding backpanel to maintain engineered forced air cooling induction paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Clearance Envelope\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnforce a minimum continuous clearance zone of 150 mm on both top and bottom edges of the Frame 5 chassis to avoid heat stagnation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Clamps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExpose the high-coverage braided shield of the motor conductor and bolt it down directly to the drive chassis grounding bus bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Torque Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply precise manufacturer-rated nominal torque limits to all power line input, motor output, and internal DC link connection lugs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Hardware Operations FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat electrical path modifications are introduced by the integrated CM jumper?\u003c\/p\u003e\n\u003cp\u003eThe default installed CM jumper bridges internal common-mode EMI filter capacitors directly to chassis ground for optimized electrical balance on grounded grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan option cards or network modules be hot-swapped during active operations?\u003c\/p\u003e\n\u003cp\u003eNo. The control architecture does not support hot-swap deployment. Complete isolation from input lines and total bus discharge are mandatory prior to board servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal DB transistor interface with regenerative loads?\u003c\/p\u003e\n\u003cp\u003eThe internal DB transistor measures the voltage across the DC link bus and automatically routes excess kinetic energy to external braking resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical architecture adjustments are required for the HIM Blank configuration?\u003c\/p\u003e\n\u003cp\u003eThis model contains no integrated interface panel; parameters must be read and adjusted via external terminal programs or network control software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this configuration permit direct linkage to a common DC bus system?\u003c\/p\u003e\n\u003cp\u003eYes. This model includes physical DC terminals alongside the AC input, allowing integration into standard DC bus power distribution topologies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal power module control high initial line inrush currents?\u003c\/p\u003e\n\u003cp\u003eAn integrated internal precharge circuit limits high inrush current through the rectifiers until the DC bus capacitors hit operational potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility verified for cluster configurations?\u003c\/p\u003e\n\u003cp\u003eDrive firmware version compatibility must be qualified using control configuration software to match the current master controller image.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the embedded I\/O layer electrically isolated from the high-voltage inverter stages?\u003c\/p\u003e\n\u003cp\u003eYes. The embedded control board uses optical barriers to insulate digital and analog communication paths from high-voltage transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066463703213,"sku":"20F11NC104JA0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-24_2617156f-2682-4b7a-b8da-811aa8096a10.jpg?v=1782447084","url":"https:\/\/www.maxwellplc.com\/ga\/products\/20f11nc104ja0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}