{"product_id":"20f11gc011ja0nnnnn-allen-bradley-powerflex-753-ac-frequency-converter","title":"20F11GC011JA0NNNNN Allen-Bradley PowerFlex 753 AC Frequency Converter","description":"\u003cp\u003eConfigured for variable frequency motor speed and torque regulation in automated industrial networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11GC011JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Frequency Converter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Component Blueprint\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric code 20F11GC011JA0NNNNN maps to a precise factory physical hardware specification. Every character determines an unalterable processing or electrical sub-component, encompassing the integrated internal EMC filtering option, specific Frame 2 structural spacing, and Type 12 \/ IP54 physical protective enclosure, which must be managed collectively as a single engineering asset.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11GC011JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 x 59.5 x 17 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW ND \/ 5.5 kW HD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC, 3 Phase \/ 540 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.5 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP54, NEMA\/UL Type 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiltered, CM Jumper Installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Braking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDB Transistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHuman Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlank (No HIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal processing architecture is designed to sustain continuous communication synchronization over EtherNet\/IP deterministic networks. The drive firmware supports active parameter mapping to control registers without degrading backplane bus communication velocity licenses. This ensures high-speed I\/O density scaling when exchanging torque, velocity, and diagnostic words with Logix-based automation controllers while adhering to established firmware flash compatibility matrices.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F11GC011JA0NNNNN AC Frequency Converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Pre-installed Internal Common Mode Jumper Assembly Set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Set of Protective Conduit Hole Plugs for Type 12 Enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Instructions\u003c\/h3\u003e\n\u003ch3\u003eEnclosure Orientation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBolt the IP54 \/ Type 12 chassis vertically onto a flat, solid vertical support structure inside the plant layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum clearance spaces at the top and bottom of the Frame 2 unit to permit proper forced air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Termination and Isolation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse dedicated conduits to isolate incoming three-phase 400 V AC or 540 V DC lines from low-voltage signal pathways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBond a low-impedance heavy gauge ground wire from the PE terminal directly to the enclosure main ground busbar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Technical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the ambient temperature threshold for standard operation?\u003c\/p\u003e\n\u003cp\u003eThe hardware maintains operational performance boundaries within a range of 0 to 50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping option cards permitted while the system is powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap behaviors are strictly unsupported; all primary and control voltages must be disabled first.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific power capacities under different load conditions?\u003c\/p\u003e\n\u003cp\u003eThe Frame 2 configuration yields an output current of 11.5 Amps, delivering 5.5 kW Normal Duty and 5.5 kW Heavy Duty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical constraints apply to installation spaces and freight calculation?\u003c\/p\u003e\n\u003cp\u003eThe drive weighs 8 kg and requires a physical outline volume of 21 x 59.5 x 17 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of environmental seal protection is provided by this enclosure?\u003c\/p\u003e\n\u003cp\u003eThe dust-tight and splash-resistant construction provides certified NEMA\/UL Type 12 and IP54 environmental ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the default condition of the internal common mode capacitor configuration?\u003c\/p\u003e\n\u003cp\u003eThe drive is delivered with the internal CM jumper fully installed, matching grounded power system layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat internal configuration options are included for braking performance?\u003c\/p\u003e\n\u003cp\u003eThis model comes configured with an integrated internal DB Transistor, though dynamic braking resistors are separate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of human interface option is integrated into the front chassis?\u003c\/p\u003e\n\u003cp\u003eThis configuration features a HIM Blank cover plate, meaning no integrated Human Interface Module is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066461704365,"sku":"20F11GC011JA0NNNNN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-66_4582ff67-0d1b-4f1f-9c46-6a4f0ce5ad22.jpg?v=1782451399","url":"https:\/\/www.maxwellplc.com\/ga\/products\/20f11gc011ja0nnnnn-allen-bradley-powerflex-753-ac-frequency-converter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}