{"product_id":"2098-dsd-010x-dn-allen-bradley-ultra-3000-servo-drive","title":"2098-DSD-010X-DN Allen-Bradley Ultra 3000 Servo Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2098-DSD-010X-DN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUltra 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServo Drive utilized to execute closed-loop positioning profiles and indexing trajectories across DeviceNet network control platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configurations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2098\u003c\/strong\u003e: Bulletin number for digital motion control drive hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDSD\u003c\/strong\u003e: Digital Servo Drive base series specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e010\u003c\/strong\u003e: 1 kW output power calibration designator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e: Indexing software functionality package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDN\u003c\/strong\u003e: Integrated DeviceNet communication interface hardware module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2098-DSD-010X-DN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kg (4 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.1 cm x 19.7 cm x 12.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot stated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100-240 VAC, 1 PH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-15 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLogic Control Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24 VDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Topology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Architecture fieldbus interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Indexing functions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Architecture and Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe digital servo unit processes motion trajectories via the integrated DeviceNet interface, establishing a deterministic real-time fieldbus network loop with host controllers. High-velocity synchronization loop parameters govern current, velocity, and position matrices. Internal firmware flash compatibility guarantees continuous tracking loop execution with low jitter, facilitating precise axis tuning and I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 2098-DSD-010X-DN Digital Servo Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Placement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMount the unit vertically within an industrial enclosure layout. Maintain standard engineering clearances around the chassis borders to optimize ambient air movement through the internal heatsink fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect single-phase AC source lines to the main terminal points. Run the 12\/24 VDC auxiliary logic loop via independent power lines to sustain memory backup functions during main power interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute DeviceNet communication drop lines through high-shield industrial cables. Separate low-voltage sensor feedback and network tracks from high-voltage AC input and motor output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Infrastructure Verification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this servo drive configuration hot-swappable?\u003c\/p\u003e\n\u003cp\u003eNo, the module cannot be extracted or inserted into power termination points while the input line or common DC bus is energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication network architecture does this model deploy?\u003c\/p\u003e\n\u003cp\u003eThis specific hardware profile coordinates multi-axis operations through an integrated DeviceNet deterministic fieldbus network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this unit feature an integrated human-machine panel?\u003c\/p\u003e\n\u003cp\u003eThis model relies on external machine interface software via serial or network ports for raw axis calibration and tuning loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the proper orientation when mounting this module?\u003c\/p\u003e\n\u003cp\u003eThe drive must be secured vertically to flat metal backplates to facilitate correct thermal air movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the auxiliary logic supply be implemented?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes an external 12\/24 VDC auxiliary power supply input to maintain network tracking when the main line power is isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of incorrect fieldbus shielding termination?\u003c\/p\u003e\n\u003cp\u003eImproper grounding of the DeviceNet communication shield leads to data packet corruption and network timing latency faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit run on three-phase line inputs?\u003c\/p\u003e\n\u003cp\u003eThis 1 kW low-voltage drive module is engineered strictly for single-phase input balancing networks across the 100-240 VAC range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are firmware structures synchronized during replacement?\u003c\/p\u003e\n\u003cp\u003eThe replace drive component must match the original host axis firmware generation parameter set to avoid initialization control errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066461147309,"sku":"2098-DSD-010X-DN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2098-DSD-010X-DN_1.jpg?v=1783255521","url":"https:\/\/www.maxwellplc.com\/ga\/products\/2098-dsd-010x-dn-allen-bradley-ultra-3000-servo-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}