{"product_id":"2094-am01-allen-bradley-kinetix-6000-axis-module","title":"2094-AM01 Allen-Bradley Kinetix 6000 Axis Module","description":"\u003cp\u003eConfigured for multi-axis motion control in automated platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2094-AM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e2094-AM01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAxis Module) provides direct physical\/electrical execution. This Kinetix 6000 series inverter module operates on a 200\/230 VAC input to deliver 1.9 kW of power at 9 A output. The module functions as a drive axis within the integrated Kinetix 6000 motion control system, facilitating high-speed motor commutation without the safe torque-off (STO) feature.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2094-AM01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.6 cm x 22.9 cm x 17.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200\/230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.9 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe 2094-AM01 is designed to operate within the Kinetix 6000 power rail, utilizing the internal backplane bus to maintain high-speed communication with the axis control module. The drive firmware supports deterministic feedback loops, ensuring accurate position and velocity tracking. Firmware flash compatibility is supported, allowing for updates to motion control parameters. Users must ensure that I\/O density scaling on the host controller is properly configured to support the specific current rating of this 9 A inverter module within the drive train.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 2094-AM01 Axis Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation and maintenance documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the axis module onto the Kinetix 6000 power rail, ensuring the power and signal connectors are fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the module using the integrated captive screws to ensure a proper chassis ground connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the motor power leads and feedback cables to the designated front-facing terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute motor power cables away from signal and feedback cabling to prevent induced noise and potential commutation errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the input voltage matches the 200\/230 VAC rating before energizing the bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module include safe torque-off (STO)?\u003c\/p\u003e\n\u003cp\u003eNo, the 2094-AM01 does not include the STO feature; appropriate external hardware must be used for safety-rated stop requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 2094-AM01 hot-swappable?\u003c\/p\u003e\n\u003cp\u003eNo, this module must be removed and installed only when the system power is completely de-energized to prevent electrical damage to the power rail connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the module is installed on an incompatible rail?\u003c\/p\u003e\n\u003cp\u003eMechanical keys and electrical interlocks are designed to prevent the module from mating with incompatible rail segments; do not force the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module status monitored?\u003c\/p\u003e\n\u003cp\u003eStatus is indicated by the LEDs on the faceplate, which provide diagnostics for communication status, fault conditions, and power presence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be used with different Kinetix series?\u003c\/p\u003e\n\u003cp\u003eNo, the 2094-AM01 is specifically engineered for the Kinetix 6000 multi-axis system and is not cross-compatible with Kinetix 5000 or 7000 series drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the required bus voltage?\u003c\/p\u003e\n\u003cp\u003eThe module requires a 200\/230 VAC input from the shared power bus; verify the bus supply capacity meets the total load requirements of all installed axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are firmware updates managed?\u003c\/p\u003e\n\u003cp\u003eFirmware is managed via the motion control software through the communication interface of the Kinetix 6000 axis control module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of failing to tighten mounting screws?\u003c\/p\u003e\n\u003cp\u003ePoor mechanical contact will prevent the module from achieving a proper ground connection, leading to intermittent communication faults and increased electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460852397,"sku":"2094-AM01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2094-AM01_1.jpg?v=1783256570","url":"https:\/\/www.maxwellplc.com\/ga\/products\/2094-am01-allen-bradley-kinetix-6000-axis-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}