{"product_id":"200350-02-00-01-bently-nevada-2300-vibration-monitors-accelerometers","title":"200350-02-00-01 Bently Nevada 2300 Vibration Monitors Accelerometers","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 200350-02-00-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e200350\u003c\/strong\u003e Accelerometer, operates as a dedicated vibration sensing component for casing acceleration measurement within Bently Nevada 2300 Vibration Monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe 200350 series configuration identifies the mechanical mounting, electrical sensitivity, and hazardous area approval options. The 02-00-01 variant provides a stainless steel mounting interface, 100 mV\/g sensitivity, and CSA, ATEX, IECEx approvals.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e200350-02-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e2300 Vibration Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.2 x 10.7 x 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g +\/-20% (10.2 mV\/m\/s2 +\/-20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Stud\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 to M8 x 1.25 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 200350-02-00-01 accelerometer converts mechanical casing vibration into an electrical acceleration signal. The sensor uses a stainless steel housing with a 1\/4-28 female mounting thread and supports direct connection to vibration monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eThe unit provides a nominal sensitivity of 100 mV\/g with a tolerance of +\/-20%. The mounting stud configuration supports mechanical installation requirements for industrial vibration monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics Signal Measurement\u003c\/h3\u003e\n\u003cp\u003eBently Nevada vibration sensors are designed for machinery condition monitoring where vibration amplitude and frequency response are evaluated by monitoring systems. The sensor output is used for vibration analysis, including rotor dynamics evaluation, mechanical imbalance detection, and casing vibration trending.\u003c\/p\u003e\n\u003cp\u003eSignal installation requires proper cable shielding and grounding practices to minimize electrical interference. Shield termination should follow the monitoring system grounding specification to reduce measurement noise and cross-talk effects.\u003c\/p\u003e\n\u003ch3\u003eEddy Current and Vibration Signal Interface Considerations\u003c\/h3\u003e\n\u003cp\u003eThe 200350 accelerometer belongs to the Bently Nevada vibration monitoring ecosystem, where sensor scaling and signal conditioning are matched with monitoring hardware input requirements. Unlike eddy-current proximity probes that measure shaft displacement and gap voltage, this accelerometer provides casing acceleration measurement signals.\u003c\/p\u003e\n\u003cp\u003eThe sensor is applied where acceleration-based vibration data is required for machinery diagnostic calculations and vibration protection logic.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 200350-02-00-01 Accelerometer\u003c\/li\u003e\n\u003cli\u003e1 x Stainless steel mounting stud configuration\u003c\/li\u003e\n\u003cli\u003e1 x Manufacturer-standard sensor assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional cables, calibration documentation, software, and accessories are not included unless specifically listed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the sensor on a rigid machine casing surface suitable for vibration measurement.\u003c\/li\u003e\n\u003cli\u003eVerify the mounting thread condition before installation.\u003c\/li\u003e\n\u003cli\u003eEnsure the mounting stud is tightened according to mechanical installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Connection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse shielded signal cabling compatible with the monitoring system input.\u003c\/li\u003e\n\u003cli\u003eMaintain cable routing separation from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the vibration monitoring system grounding method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the installation environment matches the approved CSA, ATEX, and IECEx requirements.\u003c\/li\u003e\n\u003cli\u003eProtect cable connections from mechanical stress and contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of vibration does the 200350-02-00-01 measure?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe accelerometer measures casing vibration acceleration and provides an electrical output proportional to vibration acceleration levels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs the 200350-02-00-01 a proximity probe?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. This device is an accelerometer and does not measure shaft displacement or provide eddy-current gap voltage output.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the sensor sensitivity specification?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sensor provides 100 mV\/g sensitivity with a tolerance of +\/-20%, equivalent to 10.2 mV\/m\/s2 +\/-20%.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat mounting connection is used on this model?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit uses a 1\/4-28 female mounting thread with a stainless steel mounting stud configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this sensor require external power?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe accelerometer is a passive vibration sensing device and does not have a specified external power consumption requirement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat approvals are available for this configuration?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 200350-02-00-01 configuration includes CSA, ATEX, and IECEx approval options.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan this sensor be installed with unshielded cable?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eShielded cabling is recommended for vibration signal transmission to reduce electrical interference and signal distortion.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow should the sensor output be connected?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe output should be connected to compatible Bently Nevada vibration monitoring hardware following the system wiring requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025223569581,"sku":"130539-14","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-59_67178463-f520-4c7a-ae60-b8637ccb7ec1.jpg?v=1785738144","url":"https:\/\/www.maxwellplc.com\/ga\/products\/200350-02-00-01-bently-nevada-2300-vibration-monitors-accelerometers","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}