{"product_id":"1khw001223r0002-p4lt-abb-etl600-series-signal-processing-module","title":"1KHW001223R0002 P4LT ABB ETL600 Series Signal Processing Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB 1KHW001223R0002 P4LT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP4LT\u003c\/strong\u003e Signal Processing Module, operates as a dedicated hardware component for LF to RF signal conversion and channel multiplexing within ETL600 Telecommunication Systems.\u003c\/p\u003e\n\u003ch3\u003eModel Structure and Hardware Assembly\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Part Identifier\u003c\/strong\u003e: 1KHW001223R0002 P4LT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Platform Code\u003c\/strong\u003e: P4LT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: ETL600 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff Code\u003c\/strong\u003e: 8537101190\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Sweden\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1KHW001223R0002 P4LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20 x 11.5 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubrack Backplane Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion\u003c\/td\u003e\n\u003ctd\u003eLF (Low Frequency) to RF (Radio Frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated DPLC Interface\u003c\/td\u003e\n\u003ctd\u003eMOD600 Modem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AF Modem Sub-Modules\u003c\/td\u003e\n\u003ctd\u003eUp to 4 x NSK600 Modems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplexing Architecture\u003c\/td\u003e\n\u003ctd\u003eMUX600 Data-Multiplexer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration and Deterministic Data Handling\u003c\/h3\u003e\n\u003cp\u003eThe 1KHW001223R0002 P4LT hardware interfaces directly into the subrack backplane, ensuring high backplane bus communication velocity across system slots. Dynamic bandwidth assignment allows integration with up to four NSK600 AF modems alongside the MOD600 DPLC modem. Built-in firmware flash compatibility maintains signal synchronism through the MUX600 multiplexing structure under high channel-density scaling.\u003c\/p\u003e\n\u003ch3\u003eStandard Shipping Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 1KHW001223R0002 P4LT ETL600 Signal Module\u003c\/li\u003e\n\u003cli\u003e1 x Protective Electrostatic Discharge Shield Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Shielding Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSubrack Insertion Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the backplane rack section before aligning the circuit card with the frame chassis slots.\u003c\/li\u003e\n\u003cli\u003ePress firm on the front ejector handles to seat the rear multi-pin connector into the backplane receptacle without pin bending.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRF and Ground Connection Rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate all high-frequency signal lines using shielded coaxial cabling rated for target line impedance.\u003c\/li\u003e\n\u003cli\u003eAttach low-impedance grounding straps between the rack chassis and central cabinet earthing bus prior to power application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary signal transformation is executed by the 1KHW001223R0002 P4LT module?\u003c\/p\u003e\n\u003cp\u003eThe module converts internal low-frequency (LF) baseband voice and data signals into high-frequency radio frequency (RF) bands for line transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many voice or data modems can be connected simultaneously to the board?\u003c\/p\u003e\n\u003cp\u003eThe board architecture supports direct integration of up to four NSK600 audio frequency (AF) modems alongside the MOD600 DPLC modem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module powered within the chassis assembly?\u003c\/p\u003e\n\u003cp\u003eOperational power is drawn directly from the regulated DC system power supply through the backplane bus interface connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed during active transmission cycles?\u003c\/p\u003e\n\u003cp\u003eRack power to the specific slot must be isolated before insertion or removal to prevent signal corruption on active channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat data multiplexer unit operates on this card assembly?\u003c\/p\u003e\n\u003cp\u003eThe module utilizes the MUX600 data-multiplexer architecture to consolidate multiple voice and teleprotection channels into the RF spectrum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane communication speed impact signal latency?\u003c\/p\u003e\n\u003cp\u003eHigh-velocity bus architecture minimizes propagation delay during LF-to-RF conversion and multiplexing steps across the ETL600 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions must be observed regarding electrostatic discharge during handling?\u003c\/p\u003e\n\u003cp\u003eEngineers must wear a grounded wrist strap attached to chassis earth when handling the unshielded circuit board edges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require physical calibration of RF output levels upon installation?\u003c\/p\u003e\n\u003cp\u003eParameter configuration and gain levels are managed via firmware flash setup and software tool interfaces upon system power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021075042477,"sku":"1KHW001223R0002","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_1khw001223r0002p4lt_1.jpg?v=1787888454","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1khw001223r0002-p4lt-abb-etl600-series-signal-processing-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}