{"product_id":"1khw000599r0001-abb-nsd570-teleprotection-system-interface-card-module","title":"1KHW000599R0001 ABB NSD570 Teleprotection System Interface Card Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB 1KHW000599R0001 G1LA NSD570\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eG1LA NSD570\u003c\/strong\u003e Interface Card Module, operates as a dedicated hardware component for communication interface processing within ABB power system telecommunication platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Reference\u003c\/h3\u003e\n\u003cp\u003eThe ABB 1KHW000599R0001 G1LA NSD570 is an interface card module designed for ABB NSD570 teleprotection equipment. It provides communication path adaptation between protection systems and external transmission media including power line carrier, fiber-optic, copper pilot cables, and microwave-radio links.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1KHW000599R0001 G1LA NSD570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterface Card Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eABB NSD570 Teleprotection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4 x 18.6 x 26.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003ePower line carrier (PLC) links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface Support\u003c\/td\u003e\n\u003ctd\u003eFiber-optic links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Interface Support\u003c\/td\u003e\n\u003ctd\u003eCopper wires \/ pilot cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Interface Support\u003c\/td\u003e\n\u003ctd\u003eMicrowave-radio links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Telecommunication Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe G1LA NSD570 interface card module is designed for ABB teleprotection communication systems where deterministic signal transmission is required between protection equipment and communication networks. The module provides interface adaptation for multiple transmission media used in power system protection communication.\u003c\/p\u003e\n\u003cp\u003eABB protection communication platforms require correct firmware flash compatibility and hardware configuration between interface modules and system controllers. Communication channel parameters must be configured according to the installed transmission medium and network topology.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 1KHW000599R0001 G1LA NSD570 Interface Card Module\u003c\/li\u003e\n\u003cli\u003e1 x Original interface circuit board assembly\u003c\/li\u003e\n\u003cli\u003eStandard connectors and electrical interfaces according to ABB NSD570 configuration\u003c\/li\u003e\n\u003cli\u003eCommunication cables, protection relays, and external communication equipment are not included unless specified separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module designation before installation into an ABB NSD570 chassis.\u003c\/li\u003e\n\u003cli\u003eDisconnect system power before removing or inserting the interface card.\u003c\/li\u003e\n\u003cli\u003eConfirm communication wiring type matches the configured interface channel.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable shielding and grounding for copper communication connections.\u003c\/li\u003e\n\u003cli\u003eAvoid routing communication cables near high-voltage switching conductors.\u003c\/li\u003e\n\u003cli\u003eVerify channel configuration after module installation and system restart.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Communication Interface Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe ABB G1LA NSD570 module operates within ABB teleprotection communication architectures where protocol handling, channel selection, and interface conversion are managed through the NSD570 platform. The module supports communication media selection including PLC links, optical transmission, copper pilot cables, and microwave-radio communication paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of ABB 1KHW000599R0001?\u003c\/p\u003e\n\u003cp\u003eThe module provides communication interface functions for ABB NSD570 teleprotection systems and external transmission channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich communication media are supported?\u003c\/p\u003e\n\u003cp\u003eThe module supports power line carrier links, fiber-optic links, copper pilot cables, and microwave-radio communication connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this module a standalone communication controller?\u003c\/p\u003e\n\u003cp\u003eNo. The interface card operates as part of an ABB NSD570 teleprotection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support fiber-optic communication?\u003c\/p\u003e\n\u003cp\u003eYes. Fiber-optic link interfaces are included within supported NSD570 communication configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes installation require system parameter configuration?\u003c\/p\u003e\n\u003cp\u003eYes. Communication channel parameters must be configured according to the installed NSD570 system setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the interface card be removed during operation?\u003c\/p\u003e\n\u003cp\u003ePower isolation is recommended before removal or replacement to prevent electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wiring precautions are required?\u003c\/p\u003e\n\u003cp\u003eShielded communication wiring and correct grounding practices should be applied for signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs firmware compatibility required after replacement?\u003c\/p\u003e\n\u003cp\u003eYes. The installed interface module must match the NSD570 system firmware and hardware configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021081989293,"sku":"1KHW000599R0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1KHW000599R0001.webp?v=1786355000","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1khw000599r0001-abb-nsd570-teleprotection-system-interface-card-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}