{"product_id":"1747-ocpcm2-allen-bradley-pcmcia-interface-module-slc-500-series","title":"1747-OCPCM2 Allen-Bradley PCMCIA Interface Module SLC 500 Series","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1747-OCPCM2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1747-OCPCM2\u003c\/strong\u003e PCMCIA Interface Module, operates as a dedicated hardware interface component for PC Card communication and memory expansion functions within SLC 500 controller platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1747-OCPCM2 is an SLC 500 series PCMCIA interface module designed for PC Card connectivity. The module supports 3.3 V or 5 V PCMCIA operating voltage compatibility and provides an interface between compatible SLC hardware environments and PC Card devices.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1747-OCPCM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePCMCIA Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 x 13 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 V or 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePCMCIA (PC Card) Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e1747OCPCM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1747-OCPCM2 provides PCMCIA interface capability within the SLC 500 architecture. The module voltage selection supports PC Card devices requiring either 3.3 V or 5 V operation.\u003c\/p\u003e\n\u003cp\u003eThe module installation requires compatibility with the designated SLC 500 hardware configuration. Electrical connection depends on the installed controller chassis and supported interface requirements.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Control Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley SLC 500 modules use chassis backplane communication for interaction between processor modules, communication modules, and interface devices. The 1747-OCPCM2 extends the controller hardware interface capability by providing PCMCIA card connectivity.\u003c\/p\u003e\n\u003cp\u003eThe module belongs to the Allen-Bradley industrial control platform where firmware compatibility, processor support, and configured application requirements must be verified before integration.\u003c\/p\u003e\n\u003cp\u003eBackplane communication performance depends on the installed SLC processor, chassis configuration, and application program requirements. Proper module addressing and system configuration are required for normal operation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1747-OCPCM2 PCMCIA Interface Module\u003c\/li\u003e\n\u003cli\u003e1 x SLC 500 compatible module housing\u003c\/li\u003e\n\u003cli\u003e1 x PCMCIA interface connection assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible Allen-Bradley SLC 500 chassis location.\u003c\/li\u003e\n\u003cli\u003eRemove chassis power before module installation or removal.\u003c\/li\u003e\n\u003cli\u003eConfirm module connector alignment before securing the hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePC Card Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify PC Card voltage compatibility before insertion.\u003c\/li\u003e\n\u003cli\u003eUse supported PCMCIA devices according to system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eAvoid inserting or removing cards during active data operations unless permitted by system procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain installation conditions within the specified operating temperature range.\u003c\/li\u003e\n\u003cli\u003ePrevent condensation exposure in high humidity environments.\u003c\/li\u003e\n\u003cli\u003eKeep module surfaces free from conductive dust and contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat controller family is the 1747-OCPCM2 designed for?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1747-OCPCM2 is designed for Allen-Bradley SLC 500 series controller systems and compatible module chassis configurations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of interface does the module provide?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module provides a PCMCIA (PC Card) interface for compatible card-based devices within the SLC 500 hardware environment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat voltage levels are supported by the PCMCIA interface?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module supports PCMCIA operating voltages of 3.3 V and 5 V according to connected PC Card requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the 1747-OCPCM2 be installed in a ControlLogix chassis?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The module is part of the SLC 500 platform and is not specified for ControlLogix chassis installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat environmental temperature range is supported?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified operating temperature range is 0 deg C to 60 deg C for normal module operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the module require special wiring connections?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module uses internal chassis connections. External wiring requirements depend on the connected PC Card device and system configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs power removal required during module replacement?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePower should be removed before installing or removing the module unless the system documentation specifically allows live replacement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat humidity range applies to this module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified humidity range is 5% to 95% relative humidity, non-condensing, during operation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066410651821,"sku":"1747-OCPCM2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1747-OCPCM2-0.jpg?v=1785929698","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1747-ocpcm2-allen-bradley-pcmcia-interface-module-slc-500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}