{"product_id":"1746-itv16-allen-bradley-slc-500-fast-response-dc-sourcing-input-module","title":"1746-ITV16 Allen-Bradley SLC 500 Fast Response DC Sourcing Input Module","description":"\u003cp\u003eDesigned specifically for high-speed discrete signal acquisition within Allen-Bradley SLC 500 modular control architectures, the \u003cstrong\u003e1746-ITV16\u003c\/strong\u003e Fast Response DC Sourcing Input Module processes sixteen independent 24 VDC input points with rapid response characteristics to minimize latency in time-critical industrial control sequences.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n\u003ctd\u003e1746-ITV16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Revision \/ Spare ID\u003c\/td\u003e\n\u003ctd\u003e1746-ITV16\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Density\u003c\/td\u003e\n\u003ctd\u003e16 Points (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current per Point\u003c\/td\u003e\n\u003ctd\u003e8 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage Maximum\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e0.085 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFunctional Operation \u0026amp; Circuit Behavior\u003c\/h3\u003e\n\u003cp\u003eThe module accepts DC-originating field signals through a sourcing configuration, where current flows outward from the input terminal through the field device to common. Each of the sixteen channels incorporates dedicated filtering designed for fast response applications, ensuring that transient high-speed pulses or rapid state transitions from encoders, optical sensors, or high-frequency limit switches are captured accurately without debounce delays causing missed logic states.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Parameters\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower isolation: Always disconnect chassis backplane power before inserting or extracting the module to prevent electrical arcing or memory corruption.\u003c\/li\u003e\n\u003cli\u003eSlot allocation: The module can occupy any available I\/O slot within a local SLC 500 chassis or expansion rack.\u003c\/li\u003e\n\u003cli\u003eTerminal block: Utilizes a removable terminal block (RTB) on the front face, allowing field wiring to remain undisturbed during module replacement.\u003c\/li\u003e\n\u003cli\u003eCable routing: Separate low-voltage DC input wiring from high-voltage AC power lines and variable frequency drive motor cables to mitigate electromagnetic induction and signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the primary difference between standard input modules and this fast response variant?\u003c\/li\u003e\n\u003cli\u003eA: The fast response circuitry minimizes internal filter delays, allowing the controller to register rapid pulse trains or short-duration input state changes more quickly than standard modules.\u003c\/li\u003e\n\u003cli\u003eQ: Can this module interface with sinking field devices?\u003c\/li\u003e\n\u003cli\u003eA: No. The 1746-ITV16 is engineered exclusively for sourcing-type field wiring where current flows out of the input terminal to the sensor.\u003c\/li\u003e\n\u003cli\u003eQ: How much power does the module draw from the controller chassis?\u003c\/li\u003e\n\u003cli\u003eA: It draws 0.085 A from the 5 VDC backplane supply, contributing to a total thermal dissipation load of 3.6 W across the module housing.\u003c\/li\u003e\n\u003cli\u003eQ: What is the allowable voltage window for a logic-high state?\u003c\/li\u003e\n\u003cli\u003eA: The input voltage range spans from 10 VDC to 30 VDC, with anything below 5 VDC recognized safely as an off-state condition.\u003c\/li\u003e\n\u003cli\u003eQ: Is hot-swapping supported on the SLC 500 backplane?\u003c\/li\u003e\n\u003cli\u003eA: No. Power to the chassis must be completely shut off prior to removing or installing any 1746 series I\/O module.\u003c\/li\u003e\n\u003cli\u003eQ: What size wire is recommended for the removable terminal block?\u003c\/li\u003e\n\u003cli\u003eA: Standard industrial copper wire ranging from 22 to 14 AWG is typically utilized, ensuring secure terminal screw torque to prevent intermittent connections.\u003c\/li\u003e\n\u003cli\u003eQ: Does the module require an external power supply for its internal logic?\u003c\/li\u003e\n\u003cli\u003eA: No. Internal logic power is derived directly from the rack backplane, while field devices require an external 24 VDC source.\u003c\/li\u003e\n\u003cli\u003eQ: What steps should be taken if an input channel fails to register state changes?\u003c\/li\u003e\n\u003cli\u003eA: Verify external 24 VDC supply levels, check terminal torque, confirm correct source\/sink polarity wiring, and inspect module status LED indicators.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066405671085,"sku":"1746-ITV16","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-ITV16_233.jpg?v=1785148532","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1746-itv16-allen-bradley-slc-500-fast-response-dc-sourcing-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}