{"product_id":"1746-ic16-a-allen-bradley-slc-500-digital-input-module","title":"1746-IC16\/A Allen-Bradley SLC 500 Digital Input Module","description":"\u003cp\u003eConfigured for 48 V DC discrete signal acquisition within modular control chassis, the \u003cstrong\u003eAllen-Bradley 1746-IC16\/A\u003c\/strong\u003e (\u003cstrong\u003e1746-IC16\u003c\/strong\u003e) Digital Input Module provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Series\u003c\/strong\u003e: Allen-Bradley SLC 500 modular control rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Catalog Identifier\u003c\/strong\u003e: 1746-IC16 designating a 16-point digital input configuration optimized for 48 V DC signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Revision Suffix\u003c\/strong\u003e: Revision \/A defining the baseline release specification and component layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-IC16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e24.5 x 16.5 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e85 mA at 5 V DC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe module communicates discrete process data across the local SLC backplane architecture, interfacing smoothly with controller units via backplane bus communication velocity licences. Firmware flash compatibility ensures that operational updates integrate cleanly without breaking deterministic network timing. Furthermore, input density scaling allows channel monitoring expansion without introducing communication delays or processing bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-IC16\/A Digital Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal block connector interface\u003c\/li\u003e\n\u003cli\u003e1 x Hardware documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis Slot Placement: Align the printed circuit board firmly with the guide rails of an available slot in the SLC 500 chassis and press evenly until the backplane connector seats completely.\u003c\/li\u003e\n\u003cli\u003eWiring Segregation: Separate 48 V DC input conductors from high-voltage AC lines and sensitive low-level analog circuits using dedicated wire conduits to prevent electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003eTerminal Torque Verification: Ensure all screw terminals on the removable block are torqued down securely on stripped copper conductors to prevent intermittent electrical contact under high vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do the optical isolation barriers on the 48 V DC input channels protect the internal 5 V DC backplane logic during high-voltage surges?\u003c\/p\u003e\n\u003cp\u003eA: High-dielectric optocouplers provide complete galvanic separation between the external field wiring and the internal processor logic, preventing transient voltage spikes from reaching sensitive components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary electrical consequence of applying input voltages that exceed the maximum specified rating?\u003c\/p\u003e\n\u003cp\u003eA: Overvoltage conditions beyond the rated threshold can saturate the input filtering stages and cause thermal degradation of internal limiting components, potentially destroying the optocoupler stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module process high-frequency pulse trains from fast-acting sensors without signal distortion?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is engineered for standard discrete status indication and low-frequency contact closures, meaning rapid pulse trains will experience filtering delays and state-skipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal RC filter network on the 48 V DC inputs mitigate high-frequency electrical noise from nearby plant machinery?\u003c\/p\u003e\n\u003cp\u003eA: The input filtering stages attenuate brief voltage spikes and high-frequency harmonic interference, ensuring that only stable, valid DC voltage levels register as true logic states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the processor input data table if module backplane communication is suddenly interrupted?\u003c\/p\u003e\n\u003cp\u003eA: The processor registers a rack fault and freezes the input data table at the last received values or executes pre-programmed fault routines depending on configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is it necessary to use shielded twisted-pair cables when routing low-level signals through noisy industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: Shielded cabling suppresses electromagnetic and radio frequency interference, ensuring that induced voltage spikes do not cross the logic-high threshold and trigger false inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does operating the module near the upper ambient temperature limit of +60 deg C impact component lifespan?\u003c\/p\u003e\n\u003cp\u003eA: Sustained high ambient temperatures accelerate the thermal degradation of internal optocouplers and electrolytic capacitors, reducing the operational lifespan of the hardware assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the SLC 500 backplane supply power for driving external field devices connected to the input channels?\u003c\/p\u003e\n\u003cp\u003eA: No, the backplane supplies only internal logic power, requiring an external power source to supply the current routed through the field sensor loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066404327597,"sku":"1746-IC16","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-ic16_25.jpg?v=1785142342","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1746-ic16-a-allen-bradley-slc-500-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}